My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21350
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21350
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 1:46:24 PM
Creation date
1/8/2020 1:46:21 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21350
Building Department - Name
DR HORTON INC
Address
6987 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - Manual S Compliance Report <br /> wrightsofte Da <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: Hayden 2605 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton <br /> Lot 55 Blk 6 Silverado, Zephyrhills, FL <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 32540 Btuh Entering coil DB: 76APF <br /> Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F <br /> Indoor design DB: 75.0°F Total gain: 36683 Btuh <br /> Indoor RH: 50% Estimated airflow: 1367 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042''**A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Sensible capacity: 32445 Btuh 100%of load <br /> Latent capacity: 6269 Btuh 151%of load <br /> Total capacity: 38714 Btuh 106%of load SHR: 84% <br /> i <br /> Heating Equipment <br /> Design Conditions. <br /> Outdoor design DB: 40.0°F Heat loss: 28704 Btuh Entering coil DB: 69.5°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Output capacity: 37299 Btuh 130%of load Capacity balance: 33 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1367 cfm <br /> Output capacity: 8.6 kW 102%of load Temp. rise: 18 OF <br /> I <br /> Meets are all requirements of ACCA Manual S. <br /> I"1 I1tSOft 2019-Jan-2312:59:57 <br /> W <br /> 9 ® Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> AC'CA ...press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.