My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21350
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21350
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/8/2020 1:46:24 PM
Creation date
1/8/2020 1:46:21 PM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21350
Building Department - Name
DR HORTON INC
Address
6987 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Load Short Form Job: <br /> -F f- Wrightsofto Date: <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: Hayden 2605 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3098 Fax:727-815-3399 License:CAC033669 <br /> Project Information <br /> For: DR Horton <br /> Lot 55 Blk 6 Silverado, Zephyrhills, FL <br /> Design. Information <br /> Htg CIg Infiltration <br /> Outside db(°F) 40 91 Method Simplified <br /> Inside db(°F) 70 75 Construction quality Semi-tight <br /> Design TD (°F) 30 16 Fireplaces 0 <br /> Daily range - L <br /> Inside humidity (%) 50 50 <br /> Moisture difference(gr/lb) 26 54 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB042****A Cond CH14NB042****A <br /> AHRI ref Coil FB4CNP042 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER <br /> Heating input Sensible cooling 30750 Btuh <br /> Heating output 38500 Btuh @ 47°F Latent cooling 10250 Btuh <br /> Temperature rise 26 OF Total cooling 41000 Btuh <br /> Actual air flow 1367 cfm Actual air flow 1367 cfm <br /> Air flow factor 0.048 cfm/Btuh Air flow factor 0.042 cfm/Btuh <br /> Static pressure 0.56 in H2O Static pressure 0.56 in H2O <br /> Space thermostat Load sensible heat ratio 0.89 <br /> Capacity balance point=33 OF <br /> Backup: <br /> Input=9 kW, Output=29290 Btuh, 100 AFUE <br /> ROOM NAME Area Htg load CIg load Htg AVF CIg AVF <br /> (ftz) (Btuh) (Btuh) (cfm) (cfm) <br /> kitchen/living 608 7235 9496 345 399 <br /> bed 2 164 2906 2160 138 91 <br /> powder 59 950 364 45 15 <br /> flex 156 3048 2720 145 114 <br /> foyer 75 1416 840 67 35 <br /> stairs 44 0 0 0 0 <br /> bed4 181 1973 2361 94 99 <br /> bed3 184 2272 2862 108 120 <br /> wic 60 141 176 7 7 <br /> wic 2 32 849 783 40 33 <br /> m suite 277 2889 3567 138 150 j <br /> bath 135 391 353 19 15 <br /> upstairs living 234 1451 3068 69 129 <br /> stairs 2 50 0 0 0 0 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wri htsofte 2019-Jan-2312:59:57 <br /> g Right-Suite®Universal 2017 17.0.21 RSU25554 Page e 1 <br /> ..press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: E <br />
The URL can be used to link to this page
Your browser does not support the video tag.