Laserfiche WebLink
Manual S Compliance Report Job: R0818410 <br /> -P� wrightsoft° p p Date: 0 8/1 012 01 8 <br /> Entire House By. MKc <br /> Bobby Hilton Construction,Inc. Plan: 611600 <br /> 39942 Otis Allen Rd,Zephyrtills,FL33540 Phone:(813)997-0515 <br /> Project • • <br /> For. Bobby Hilton Construction,Inc. <br /> Zephyrhills,FL 33540 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 17415 Btuh Entering coil DB: 77.3'F <br /> Outdoor design WB: 772°F Latentgain: 3659 Btuh Entering coil WB: 63.8°F <br /> Indoor design DB: 75.0'F Total gain: 21074 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SplitASHP <br /> Manufacturer., Franklin or Eqv. Model: GSZ160241+ASPT29B14 <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 18000 Btuh 103%of load <br /> Latent capacity: 6000 Btuh 164%of load <br /> Total capacity: 24000 Btuh 114%ofload SHR: 75% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 15763 Btuh Entering coil DB: 69.1OF <br /> Indoor design DB: 70.0'F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipmenttype: SplitASHP <br /> Manufacturer. Franklin or Eqv. Model: GSZ160241+ASPr29B14 <br /> Actual airflow: 800 cfm <br /> Output capacity. 24000 Btuh 152%ofload Capacity balance: 33 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elecstrip <br /> Manufacturer. Model: <br /> Actual airflow: 800 cfm <br /> Output capacity. 5.0 kW 108%of load Temp.rise: 31 OF <br /> Meets all requirements ofACCA Manual S. <br /> *wrightsoft® 2018-Aug-1411:45:58 <br /> .,, •d, �.���, RigitSute®Uriversal201818.0.19RSU20773 Pagel <br /> 818410-Bobby Mon CorstructiodR0818410np CaIc=MJ8 FrortDoorfaces:E <br />