My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20205
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20205
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 1:31:30 PM
Creation date
1/13/2020 1:31:28 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-20205
Building Department - Name
HILTON JR,BOBBY E
Address
5901 13TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-� Job: R 0 <br /> wrightsoft° Project Summary Date: 08/1012018 Entire House By. MKc <br /> Bobby Hilton Construction,Inc. Plan: 611600 <br /> 39942 Otis Allen Rd,Zepftffhlls,FL33540 Phone:(813)997-0515 <br /> Project • • <br /> For. Bobby Hilton Construction,Inc. <br /> Zephyrhills,FL 33540 <br /> Notes: Load calculation was obtained from a digital copy of the CAD drawing. <br /> Design Information <br /> Weather. Tampa Intl AP,FL,US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 43 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 27 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 grAb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 12742 Btuh Structure 13002 Btuh <br /> Duds 3022 Btuh Ducts 4413 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 dm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 15763 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 17415 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Average <br /> Fireplaces 0 Structure 2352 Btuh <br /> Ducts Btu <br /> Central vent(0 dm) 1300 Btuh <br /> Heatingg Coolingg (none) <br /> Area(ft') 1382 1382 Equipment latent load 3659 Btuh <br /> Volume(fl3) 11056 11056 <br /> Air changes/hour 0.45 023 Equipment Total Load(Sen+Lat) 21074 Btuh <br /> EquIv AVF(cfm) 83 42 Req.total capacity at 0.75 SHR 1.9 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Franklin or Eqv. Make Franklin or Eqv. <br /> Trade Split HP Trade Split HP <br /> Model GSZ160241 Cond GSZ160241 <br /> AHRI ref 201667298 Coil ASPT29B14 <br /> AHRI ref 201667298 <br /> Efficiency 9 HSPF Efficiency 13.0 EER,16 SEER <br /> Heating Input Sensible cooling 18000 Btuh <br /> Heating output 24000 Btuh @47-F Latentcooling 6000 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual airflow 800 dm Actual airflow 800 cfrrl <br /> Airflowfactor 0.051 dmA3tuh Airflowfador 0.046 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.83 <br /> Capacity balance point=33 OF <br /> Backup:Aux Heat <br /> Input=5 kW, Output=17061 Btuh,100AFUE <br /> Calculations approved byACCA to meet all requirements of Manual J 8th Ed. <br /> wrigF�tsoft- 2018-A�-1411 A5:58 <br /> t •W •• Right-Sute@Uriversal2018l8.0.19RSU20773 Pagel <br /> ...818410-Bobby H lton CorstnictiorAR0818410np Calc=NUB Front Doorfaws:E <br />
The URL can be used to link to this page
Your browser does not support the video tag.