My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20205
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20205
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/13/2020 1:31:30 PM
Creation date
1/13/2020 1:31:28 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-20205
Building Department - Name
HILTON JR,BOBBY E
Address
5901 13TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: R0618410 Builder Name: Bobby Hilton Constru tion,In <br /> Street: -�'q'01 1 3 Permit Office: Viiate Parir <br /> City,State,Zip: Zephyrhills,FL,33540 Permit Number: W S- <br /> Owner. Bobby Hilton Construction,Inc. Jurisdiction: fl &116" <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zane 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1414.0 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 1117.30 ft2 <br /> b.Frame-Wood,Adjacent R=13.0 296.67 ft2 <br /> 3. Number of units,if multiple family 1 c,N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1381.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1381.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1382 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(104.1 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 225 <br /> a. U-Factor. Dbl,U=0.33 104.10 ft2 <br /> SHGC: SHGC=0.28 <br /> b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: a.Central Unit 24.0 SEER:16.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Strip Heat 24.0 COP:1.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 3.309 ft. <br /> Area Weighted Average SHGC: 0.280 14.Hot water systems <br /> 8. Floor Types (1382.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.970 <br /> a.Slab-On-Grade Edge Insulation R=0.0 1382.00 ft2 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits CF,Pstat <br /> Glass/Floor Area: 0.075 Total Proposed Modified Loads: 41.96 PASS <br /> Total Baseline Loads: 43.85 <br /> I hereby certify that the plans and specifications covered by Review of the plans and OTC Srgp� <br /> this calculation are in compliance�with the Florida Energy specifications covered by this V <br /> Code. calculation indicates compliance <br /> ++ i. <br /> with the Florida Energy Code. <br /> PREPARED BY: Before construction is completed W. <br /> 08-14-18 <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed,is in compliance Florida Statutes. 1 <br /> with the Florida Energy Code. COD wn't4� <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: DATE: <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(111402.4.1.2). <br /> 8/14/2018 11:49 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.