My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20277
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20277
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:15:59 AM
Creation date
1/13/2020 1:32:34 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-20277
Building Department - Name
CREWS,JAMIE R
Address
40134 CHANCEY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
- - wrightsoft° Manual S Compliance Report Job: R0818445 <br /> -Date: 08-31-18 <br /> AHU1 By: TnnN <br /> Pete Richter Construction Inc Plan: City ofZephymius <br /> PO Box 1201,San Antonio,FL 33575 Phone:352-263-7566 <br /> Project Information <br /> For: Jamie Crews <br /> 40134 Chancey Rd, Zephyrhills, FL 33540 <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 22536 Btuh Entering coil DB: 80.6°F <br /> Outdoor design WB: 77.2°F Latent gain: 6918 Btuh Entering coil WB: 65.VF <br /> Indoor design DB: 75.0°F Total gain: .29458 Btuh <br /> Indoor RH: 50% Estimated airflow: 1140 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: 3 Ton- Goodman or Model: GSZ160361B+AVPTC37C14A <br /> Actual airflow: 1140 cfm <br /> Sensible capacity: 28526 Btuh 127%of load <br /> Latent capacity: 5464 Btuh 79%of load <br /> Total capacity: 33990 Btuh 115%of load SHR: 84% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 22828 Btuh Entering coil DB: 69.2°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions" <br /> Equipment type: SpIitASHP <br /> Manufacturer: 3 Ton- Goodman or Model: GSZ160361B+AVPTC37C14A <br /> Actual airflow: 1.140 cfm <br /> Output capacity:. 35000 Btuh 153% of load Capacity balance: 33 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1140 cfm <br /> Output capacity: 5.0 kW 75%of load Temp. rise: 22 OF <br /> Meets all requirements of ACCA Manual S. <br /> -F- wrightsoft- 2018-Sep-05 22:19:15 <br /> RightSuite®Universal 2018 18.0.27 RSU07440 Page 1 <br /> ACCA CAHVAC\aWork File\R0818445-Crew\R0818445.rup Calc=MJ8 Front Door faces: N <br />
The URL can be used to link to this page
Your browser does not support the video tag.