Manual S Compliance Report Job: R0818445 <br /> +� wrightsoft� Date: b8-31-1$ <br /> AHU2 By: tMN - <br /> Pete Richter Construction Inc Plan: City of Zephyrhills <br /> PO Box 1201,San Antonio,Fl-33575 Phone:352-263-7566 <br /> Project • • <br /> For: Jamie Crews <br /> 40134 Chancey Rd,.Zephyrhills, FL 33540 <br /> Gooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 12761 Btuh Entering coil DB: 82.9°F <br /> Outdoor design WB: 77.2°F Latent gain:' 3657 Btuh Entering coil WB: '66.1°F <br /> Indoor design DB: . 75.0°F Total gain: 16418 Btuh <br /> Indoor RH: 50% Estimated airflow: 593 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: 2 Ton-Goodman or Model: GSZ160181B+AVPTC29B14A <br /> Actual airflow: 593 cfm <br /> Sensible capacity: 15217 Btuh 119% of load <br /> Latent capacity: 2658 Btuh 73% of load <br /> Total capacity: 17875 Btuh 109% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 42.9°F Heat loss: 8951 Btuh Entering coil DB: 68.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions. <br /> Equipment type: Split ASHP <br /> Manufacturer: 2 Ton-Goodman or Model: GSZ160181B+AVPTC29B14A <br /> Actual airflow: 593 cfm <br /> Output capacity: 18000 Btuh 201% of load Capacity balance: 26 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 'F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 593 cfm <br /> Output capacity: 5.0 kW 191%of load Temp. rise: 41 °F <br /> Meets all requirements ofACCA Manual S. <br /> 2018-Sep-05 22:19:15 <br /> WrlghtZS®,ft" RightSuite® 9 Universal 2018 18.0.27 RSU07440 Page 2 <br /> ACCA C:\HVAC\aWork File\R0818445-Crew\R0818445.rup Calc=M,18 Front Door faces: N <br />