My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20277
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20277
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:15:59 AM
Creation date
1/13/2020 1:32:34 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-20277
Building Department - Name
CREWS,JAMIE R
Address
40134 CHANCEY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project SummaryJob: R-31-18s <br /> wrightsoft- Date: 0831-18 <br /> • AHU1 By: TMN <br /> Pete.Richter Construction Inc Plan: City of Zephytfiius <br /> PO Box 1201;San Antonio,FL33575 Phone:'352-263-7566- <br /> • ect Information <br /> For: Jamie Crews <br /> 40134 Chancey Rd,Zephyrhills, FL 33540 <br /> Notes: Load calculation was obtained from a digital copy of drawing. <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db . 43 OF.- Outside db 91 OF <br /> Inside db 70 OF Inside db-- 75 OF,. <br /> Design TD 27 OF Design TD 16 'F <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 19305 Btuh Structure 14041 Btuh .. <br /> Ducts 2810 Btuh Ducts 1920 Btuh <br /> Central vent(24 cfm) 713 Btuh Central vent(24 cfm) 432 Btuh <br /> Outside air- Outside air <br /> Humidification 0 Btuh Blower-.: 6143 Btuh <br /> Piping 0 Btuh <br /> Equipment load 22828 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load ' 22536 Btuh <br /> Method Simplified Latent.Cooling Equipment Load Sizing' <br /> Construction quality Semi-tight <br /> Fireplaces 2(Tight) Structure' 4218 Btuh <br /> Ducts 1822 Btuh <br /> Central vent(24 cfm) 877 Btuh <br /> Heating Coolingg Outside air <br /> Area(ft2 1644 1644 Equipment latent load 6918 Btuh. . <br /> Volume(W) 24297 24297 <br /> Air changes/hour 0.33 0.17 Equipment Total Load Sen+Lat) 29453 Btuh <br /> Equiv.AVF(cfm) 134 69 Req.total capacity at 0.75 SHR 2.5 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make 3 Ton- Goodman or Eqv. Make 3 Ton-,Goodman or Eqv. <br /> Trade Split HP Trade Split HP <br /> Model 6SZ160361 B Cond GSZ160361 B <br /> AHRI ref 201680118 Coil AVPTC37C14A <br /> AHRI ref -201680118 <br /> Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER <br /> Heating input Sensible cooling 25650 Btuh <br /> Heating output. 35000 Btuh @ 47OF Latent cooling 8550 Btuh <br /> Temperature rise 28 ,,°F - Total cooling 34200 Btuh <br /> Actual air flow , 1140 cfm Actual air flow 1140 cfm <br /> Airflow factor. 0.052 cfm/Btuh" Air flow-factor 0.071, cfm%Btuh <br /> Static pressure 0.50.-.1n H2O Static pressure 0.50 in H2O <br /> Space thermostat Load sensible heat ratio 0.77. <br /> Capacity balance point=33 OF <br /> Backup: Aux. Heat <br /> Input=5 kW, Output= 17061 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wri htsoft- 2018Sep-05 22:19:15 <br /> ^'� .W..•9 - RightSuiteO Universal 2018 18.0.27 RSU0744Q Page 1 <br /> ACCK C:\HVAC\aWork F11e\110818445-Crew\R0818445.rup Calc=MJ8 Front Door faces: N <br />
The URL can be used to link to this page
Your browser does not support the video tag.