My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
18-20277
Zephyrhills
>
Building Department
>
Permits
>
2018
>
18-20277
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:15:59 AM
Creation date
1/13/2020 1:32:34 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
18-20277
Building Department - Name
CREWS,JAMIE R
Address
40134 CHANCEY RD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
wri9htsoft Project Summary Job: R0818445 <br /> Date: 08-31-18 <br /> AHU2 By: TNiN <br /> Pete Richter Construction Inc Plan:, City ofzepnymins <br /> PO Box 1201,San Antonio,FL 33575 Phone:352-263-7566 <br /> Project Information <br /> For: Jamie Crews <br /> 40134 Chancey Rd, Zephyrhills, FL 33540 <br /> Notes: Load calculation was obtained from a digital copy of drawing. <br /> Design Information <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions . Summer Design Conditions <br /> Outside db 43 °F Outside db 91 OF <br /> Inside db 70 °F Inside db 75 OF <br /> Design TD 27 OF Design TD 16 OF <br /> Daily range L" <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating.Summary Sensible Cooling.Equipment Load Sizing <br /> Structure 6730 Btuh Structure 6856 Btuh <br /> Ducts 1459 Btuh Ducts 1007 Btuh <br /> Central-vent(26 cfm) 763 Btuh Central vent(26 cfm) 462 Btuh <br /> Outside air Outside air <br /> Humidification 0 Btuh Blower 4437 Btuh <br /> Piping 0 Btuh <br /> Equipment load 8951 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 12761 Btuh <br /> Method Simplified Latent Cooling'Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 2(Tight) Structure 1827 Btuh <br /> Ducts 893 Btuh <br /> Central vent(26 cfm) 938 Btuh <br /> Heatingg Cool,ngg Outside air <br /> Area(ft2 1060 1060 Equipment latent load 3657 Btuh <br /> Volume i(ft3) 12236 12236 <br /> Air changes/hour 0..22 0.11 Equipment Total Load (Sen+Lat) 16418 Btuh <br /> Equiv.AVF(cfm) 44 23 Req.total capacity at 0.75 SHR 1.4 ton <br /> Heating Equipment Summary. Cooling Equipment Summary <br /> Make 2 Ton- Goodman or Eqv. Make 2 Ton-Goodman or Eqv. <br /> Trade Split HP Trade Split HP <br /> Model GSZ160181 B Cond GSZ160181 B <br /> AHRI ref 201680076 Coil AVPTC29B14A <br /> AHRI ref 201680076 <br /> Efficiency 9 HSPF Efficiency 13.0 EER, 16 SEER <br /> Heating:input Sensible cooling 13350 Btuh <br /> Heating output 18000 Btuh @ 47°F Latent cooling 4450 Btuh <br /> Temperature rise 28 OF Total cooling 17800 Btuh <br /> Actual air flow 593 'cfm Actual air flow 593 cfm <br /> Air flow factor 0.072 cfm/Btuh Air flow factor 0.075 cfm/Btuh <br /> Static pressure 0.50 in H2O Static pressure 0.50 in H2O <br /> Space thermostat Load sensible heat ratio 0.78 " <br /> Capacity balance point=26 OF <br /> Backup: Aux. Heat <br /> Input= 5 kW, Output= 17061 Btuh, 100 AFUE <br /> Calculations approved by ACCA to.meet all requirements of Manual J 8th Ed. <br /> -FW wrri-gMtsoft- 2018-Sep-05 22:19:15 <br /> Right-Suite®Universal 2018 18.0.27 RSU07440 Page 2 <br /> ACCK CAHVAC1aWork File1R0818445-Crew1R0818445.rup Cale=M.18 Front Door faces: N <br />
The URL can be used to link to this page
Your browser does not support the video tag.