Laserfiche WebLink
Page 2 of 2 <br /> The following values have been verified by in-house testing and the mounting hardware manufacturers' data, <br /> which are available upon request. Panel support connections should be staggered,where possible,to distribute <br /> load to adjacent;members. <br /> Modules in Lands cape Modules in Portrait <br /> Roof Zone Interior Ede Corner Interior Ede Corner <br /> Max Vertical Spacing in 40 40 40 66 66 66 <br /> Max Horizontal Spacing in 24 24 24 24 24 24 <br /> Max Uplift Load Ibs 335 267 247 566 451 417 <br /> Based on the above'evaluation, with appropriate panel anchors being utilized the roof system designed on will <br /> adequately support the additional loading imposed by the solar panels, if installed correctly.This evaluation has <br /> been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida <br /> Building Code- Residential 6th Edition, current industry standards and practice, and the information supplied to us <br /> at the time of this report. <br /> If there are any questions regarding the above, or if more information is required, please contact me. <br /> ��I1111 Ilr�iii <br /> �Regards, <br /> J. Matthew Walsh, SE, PE * N 84. 'y <br /> FL License'No. 84923 <br /> STATE OF ; <br /> i 0 • � � <br /> ON <br /> I/I11111 <br /> 12/07/2018 <br /> i <br /> ivi n <br /> �® <br />