DONNELLY ENGINEERING ELECTRICAL <br /> locations shall be as accepted by the Engineer during construction. Obtain in the field all information <br /> relevant to the placing of electrical work and in case of interference with other work, proceed as <br /> directed by the Engineer and provide all labor and materials necessary to complete the work in an <br /> acceptable manner. <br /> B. Discrepancies: Notify Engineer of any discrepancies found during construction of the project and do <br /> not proceed with that portion of the project, until a written definitive statement is received providing clear <br /> direction. If a conflict exists between the contract documents and any applicable code or standard, the <br /> most stringent requirement shall be included for this project. The Engineer shall make the decision <br /> regarding questionable areas of conflict. <br /> C. Wiring: Each three-phase circuit shall be run in a separate conduit unless otherwise shown on the <br /> Drawings. Unless otherwise accepted by the Engineer, conduit shall not be installed exposed unless <br /> specifically directed to be exposed. Where circuits are shown as "home-runs" all necessary fittings and <br /> boxes shall be provided for a complete raceway installation. Do not install more than three circuits in a <br /> single raceway. Circuit numbers indicated for new circuits shall not be changed. Use the circuit numbers <br /> indicated. <br /> D. Surface Supports: Surface mounted panel boxes, junction boxes, conduit, etc., shall be supported by <br /> spacers to provide a clearance between wall and equipment. <br /> E. Layout: Circuit layouts are not intended to show the number of fittings, or other installation details. <br /> Provide all labor and materials necessary to install and place in satisfactory operation all power, control, <br /> lighting, and other electrical systems shown. All connections to equipment shall be made as required, <br /> and in accordance with the accepted shop and manufacturer's setting drawings. <br /> F. Coordination: Coordinate final equipment locations with existing conditions. Layout before installation <br /> so that all equipment has adequate space. Provide coordination as required for installation in a neat <br /> and workmanlike manner. <br /> 1.5 EQUIPMENT SIZE AND HANDLING <br /> A. Coordination: Investigate each space in the structure through which equipment must pass to reach its <br /> final location. If necessary, the equipment shall be required to be shipped in sections of specific sizes to <br /> permit the passing through the necessary areas within the structure. <br /> B. Handling: All equipment shall be kept upright at all times. When equipment has to be tilted for ease of <br /> passage through restricted areas during transportation, the manufacturer shall be required to brace the <br /> equipment suitably, to insure that the tilting does not impair the functional integrity of the equipment. <br /> 1.6 RECORD DRAWINGS <br /> A. Production: The Contractor shall provide two (2) sets of black or blue line on white drawings to <br /> maintain and submit record "as-built drawings". One set shall be maintained at the site and at all times <br /> be accurate, clear, and complete, showing the actual location of all equipment as installed. The Record <br /> Drawings shall show actual locations of all underground lines and accurate wiring diagrams of all power, <br /> light and other systems marked in colored pencil "As Installed". The underground lines shall be shown <br /> "dashed". The "Progress As-Built" drawings shall show all Electrical work installed complete to the <br /> present stage of progress, actual routing of all branch wiring, actual routing of homeruns including all <br /> junction or pull boxes, drops and risers and the location of all junction boxes and access panels. These <br /> drawings shall be available to the Engineer's field representatives at all times. <br /> Heartland Health Care Center of Zephyrhills-3181 16010-2 DE No 217032 <br /> 38220 Henry Drive,Zephyrhills, FL 33542 Pending Emergency Rule 59A-4.1265 <br />