My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20704
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20704
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:37:06 AM
Creation date
1/14/2020 8:37:01 AM
Metadata
Fields
Template:
Building Department
Company Name
HCRA PROPERTIES I LLC
Building Department - Doc Type
Permit
Permit #
19-20704
Building Department - Name
HCRA PROPERTIES I LLC
Address
38220 HENRY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
84
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DONNELLY ENGINEERING ELECTRICAL <br /> E. Controls: Controls shall be as follows; <br /> 1. General <br /> a. The generator set shall be provided with a microprocessor based control system designed <br /> to provide the following features and functions: <br /> 1) The control system shall be mounted within the generator set and provide a suitable <br /> operator control panel. The control panel shall provide vibration isolation as <br /> necessary to the mounted controls to provide trouble free operation <br /> 2) Manual and automatic starting/stopping of the generator set shall be provided <br /> a) Automatic mode of operation shall have provisions for accepting a starting/stopping <br /> signal from a remote device <br /> b) Manual mode of operation shall be provided at the operator control panel located on <br /> the generator set <br /> 3) Monitoring and control functions for the generator set shall be provided <br /> a) Local monitoring and control shall be provided on the generator set operator control <br /> panel <br /> b) Control system shall have the capability for remote monitoring and control with the <br /> use of additional hardware, components, and cabling as noted in the text <br /> 4) Automatic annunciation or shutdown of generator set warning or alarm functions <br /> a) Local monitoring and control shall be provided on the generator set operator control <br /> panel <br /> b) Control system shall have the capability for remote monitoring and control with the' <br /> use of additional hardware, components, and cabling as noted in the text <br /> b. Control Functions <br /> 1) The control system shall include a engine cycle cranking system with adjustable <br /> settings for: <br /> a) Pre Start Delay Time <br /> b) Maximum Crank Time <br /> c) Pause Time between crank attempts <br /> d) Idle Time <br /> 2) The control system shall include an engine governing control to provide steady state <br /> frequency regulation.The governor shall include adjustments for gain,dampening, <br /> and ramping functions to control engine speed if not provided by the engine control <br /> module supplied by the engine manufacturer <br /> 3) The control system shall include adjustable time delay functions for: <br /> a) Time Delay Start <br /> b) Time Delay Stop <br /> C. Emergency Stop <br /> 1) An emergency stop switch shall be provided. Depressing the switch shall cause the <br /> generator set to shut down. The switch shall be flush mounted and located to <br /> prevent accidental operation.The switch shall be a Red mushroom type requiring a <br /> manual reset and shall be clearly marked as emergency <br /> 2. Controller Operator Display <br /> a. The generator set controller shall have the following operator display features as a <br /> minimum <br /> 1) Backlit graphical LCD display 64x128 pixel resolution minimum <br /> 2) Genset status LEDs shall provide the following indications: <br /> a) Alarm - Preferred color is Red <br /> Heartland Health Care Center of Zephyrhills-3181 16650-9 DE No 217032 <br /> 38220 Henry Drive,Zephyrhills, FL 33542 Pending Emergency Rule 59A-4.1265 <br />
The URL can be used to link to this page
Your browser does not support the video tag.