Laserfiche WebLink
DONNELLY ENGINEERING ELECTRICAL <br /> b) Not In Auto- Preferred color is Red <br /> c) Warning - Preferred color is Yellow <br /> d) Running - Preferred color is Green <br /> e) Ready/Auto-Preferred color is Green <br /> f) Supplying Load - Preferred color is Green <br /> 3) The controller panel shall be a sealed membrane type. Sealing shall meet IP64 and <br /> have operator keys for the following control functions: <br /> a) Start <br /> b) Stop <br /> c) Fault Reset <br /> d) Horn Reset <br /> e) Data Entry-Mode, Page Up, Page Down, and Enter <br /> 4) The genset controller shall display the following engine metering and protection <br /> functions: <br /> a) Running Hour Meter <br /> b) Over Speed Shutdown <br /> c) Low Oil Pressure Warning <br /> d) Low Oil Pressure Shutdown <br /> e) High Coolant Temperature Warning <br /> f) High Coolant Temperature Shutdown <br /> g) Low Coolant Temperature Warning <br /> h) Battery Under Voltage Warning <br /> i) Battery Over Voltage Warning <br /> j) Low Fuel Level Warning <br /> k) Low Fuel Level Shutdown <br /> 5) The genset controller shall display the following generator set metering and <br /> protection functions: <br /> a) Under Voltage Warning <br /> b) Under Voltage Shutdown <br /> c) Over Voltage Warning <br /> d) Over Voltage Shutdown <br /> e) Over Frequency Warning <br /> f) Over Frequency Shutdown <br /> g) Under Frequency Warning <br /> h) Under Frequency Shutdown <br /> i) Over Current Shutdown <br /> 6) The genset controller shall display the following generator set output metering <br /> functions: <br /> a) Output Voltage- Each Phase <br /> b) Output Current- Each Phase <br /> c) Output Frequency <br /> d) Output kW(kilowatt) <br /> e) Output kWh (kilowatt hours) <br /> f) Output kVAr(kilovolt-ampere Reactive) <br /> g) Output kVAh (kilovolt-ampere hours) <br /> 3. Common Alarm <br /> a. A common remote audible alarm function will be provided so that a horn output will <br /> occur. The horn shall be battery powered and resettable from the operator control <br /> panel and any remote annunciator as specified in the text. The horn will activate if <br /> any of the following conditions occur: <br /> 1) Over Crank Alarm <br /> 2) Low Coolant Temperature Warning <br /> 3) High Coolant Temperature Warning <br /> 4) High Coolant Temperature Alarm <br /> 5) Low Oil Pressure Warning <br /> Heartland Health Care Center of Zephyrhills-3181 16650-10 DE No 217032 <br /> 38220 Henry Drive,Zephyrhills, FL 33542 Pending Emergency Rule 59A-4.1265 <br /> I, \ <br />