Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-20741
Building Department - Name
LENNAR HOMES LLC
Address
35949 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 3246B sf ADSCarrierVW' <br /> Date: 111512019 <br /> upperfloor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 17771 Btuh Entering coil DB: 75.5°F <br /> Outdoor design WB: 77.2°F Latent gain: 3559 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21330 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturers Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 115% of load <br /> Latent capacity: 3600 Btuh 101% of load <br /> Total capacity: 24000 Btuh 113% of load SHR: 85% <br /> i <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 32.1°F Heat loss: 12853 Btuh Entering coil DB: 69.7'F <br /> Indoor design DB: 70.0°F <br /> Manufacturers Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 18852 Btuh 147% of load Capacity balance: 17 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 4.0 kW 105% of load Temp. rise: 50 'F <br /> Meets all requirements of ACCA Manual S. <br /> - wrightsoft® 2019-Jan-1512:47:04 <br /> �� <r•N ame ww Right-Suite®Universal 2018 18.0.16 RSU05714 <br /> Page 2 <br /> ACCK ...nt\3246 sf ADS VW template 2,2 ton Carrierrup Calc=MJ8 Front Door faces:SW <br />