Search
19-20741
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20741
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 8:56:36 AM
Creation date
1/14/2020 8:56:35 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-20741
Building Department - Name
LENNAR HOMES LLC
Address
35949 SADDLE PALM WAY
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> Manual S Compliance Report Job: 3246B sf ADS Carrier VW <br /> p p Date: 1/1512019 <br /> lower floor By: Dave Aldrich <br /> Bayonet Plumbing Heating and Cooling <br /> 8950 New York ave,Hudson <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 19700 Btuh _ Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.2°F Latent gain: 1801 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21501 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SplitASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 104% of load <br /> Latent capacity: 3600 Btuh 200% of load <br /> Total capacity: 24000 Btuh 112% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 32.1°F Heat loss: 26017 ' Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASH <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L j <br /> Actual airflow: 800 cfm <br /> Output capacity: 18859 Btuh 72% of load Capacity balance: 35 °F I' <br /> Supplemental heat required: 7158 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 7.1 kW 93% of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> t wrightsoft- 2019-Jan-1512:47:04 <br /> �� •w• ��ww--,�� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> -4CC ...nt\3246 sf ADS VW template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces:SW <br />