Laserfiche WebLink
r ` <br /> • Project Summary Job: 2575A1sf ADS CarderVW <br /> 1 Date: 1/1512019 <br /> upper floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> i <br /> Project I • • <br /> For: Lennar Homes <br /> Notes: Vinyl windows <br /> i <br /> Design Information ! <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 32 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 38 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 10229 Btuh Structure 15625 Btuh <br /> Ducts 1805 Btuh Ducts 2140 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 12034 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 17765 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 3063 Btuh <br /> Ducts 374 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heatin Coolingg (none) <br /> Area(ftz) 149� 1491 Equipment latent load 3437 Btuh <br /> Volume(W) 12077 12077 <br /> Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21202 Btuh <br /> Equiv.AVF (cfm) 54 29 Req. total capacity at 0.85 SHR 1.7 ton <br /> Heating Equipment Summary Cooling-Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.066 cfm/Btuh Air flow factor 0.045 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.84 <br /> Capacity balance point= 16 OF <br /> Backup: <br /> Input= 3 kW, Output= 11787 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> 41- wrightsoft- 2019-Jan-15 10:31:43 <br /> ^w.• w-��-� Right-Suite®Universal 2018 18.0.16 RSU05714 page 2 <br /> ...5A1 sf ADS template TIA VW 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces:SW <br />