My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20748
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20748
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 9:01:25 AM
Creation date
1/14/2020 9:01:23 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-20748
Building Department - Name
LENNAR HOMES LLC
Address
2996 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 2575A1sfADSCarrierVW <br /> Date: 1/1512019 <br /> lower floor By: Dave <br /> BAYONET PLUMBING COOLING HEATING <br /> Project • <br /> For: Lennar Homes <br /> i <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.4°F Sensible gain: 12326 Btuh Entering coil DB: 75.8°F <br /> Outdoor design WB: 77.2°F Latent gain: 1216 Btuh Entering coil WB: 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 13542 Btuh <br /> Indoor RH: 50% Estimated airflow: 600 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Sensible capacity: 15300 Btuh 124% of load <br /> Latent capacity: 2700 Btuh 222% of load <br /> Total capacity: 18000 Btuh 133% of load SHR: 85% <br /> Design Conditions Heating Equipment <br /> Outdoor design DB: 32.1 OF Heat loss: 18086 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> i <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> i <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Output capacity: 13793 Btuh 76% of load Capacity balance: 34 OF <br /> Supplemental heat required: 4293 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 600 cfm <br /> Output capacity: 4.5 kW 85% of load Temp. rise: 50 OF <br /> Meets all requirements of ACCA Manual S. <br /> -�- wrightsoft® 2010—Jan-15 10:31:43 <br /> ^'�- .dROH e��a,•m ym wm Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ...5A1 sf ADS templateTIA VW 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces:SW <br />