My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20751
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20751
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 9:04:35 AM
Creation date
1/14/2020 9:04:33 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-20751
Building Department - Name
LENNAR HOMES LLC
Address
3312 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pro ect Summal�' Job: 2575B1 sf ADS CarrierVw <br /> J '7 Date: 10/1/2018 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Notes: Vinyl windows <br /> Design Information <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 39 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 15917 Btuh Structure 10170 Btuh <br /> Ducts 1406 Btuh Ducts 1655 Btuh j <br /> Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> none <br /> Humidification 0 Btuh Blower e) 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 17322 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 11824 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 1088 Btuh <br /> Ducts 294 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1093 1093 Equipment latent load 1382 Btuh <br /> Volume(ft') 9654 9654 <br /> Air changes/hour 0.34 0.18 Equipment Total Load (Sen+Lat) 13207 Btuh <br /> Equiv.AVF(cfm) 55 29 Req. total capacity at 0.85 SHR 1.2 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC518AO0300 Cond 25HBC518AO0300 <br /> AHRI ref 9154643 Coil FB4CNP025L <br /> AHRI ref 9154643 <br /> Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER <br /> Heating input Sensible cooling 15300 Btuh <br /> Heating output 17700 Btuh @ 47°F Latent cooling 2700 Btuh <br /> Temperature rise 27 OF Total cooling 18000 Btuh <br /> Actual air flow 600 cfm Actual air flow 600 cfm <br /> Air flow factor 0.035 cfm/Btuh Air flow factor 0.051 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.90 <br /> Capacity balance point= 32 OF <br /> Backup: <br /> Input=4 kW, Output= 15295 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -F�11 wrightsoft- 2018-Oct-01 08:01:26 <br /> •-..• ^��^�M Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> ...\2575B sf ADS template VW 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.