Laserfiche WebLink
Project Summary Job: 2575B1 sfADSCanierVW <br /> J '.7 Date: 1011/2018 <br /> upperfloor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project Information <br /> For: Lennar Homes <br /> Notes: Vinyl windows <br /> Design Information <br /> Weather: Tampa International AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 31 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 39 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 55 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 9648 Btuh Structure 15955 Btuh <br /> Ducts 1844 Btuh Ducts 2139 Btuh <br /> Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 11492 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 18094 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2717 Btuh <br /> Ducts 382 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 1489 1489 Equipment latent load 3099 Btuh <br /> Volume(ft') 11912 11912 <br /> Air changes/hour 0.23 0.12 Equipment Total Load (Sen+Lat) 21192 Btuh <br /> Equiv.AVF (cfm) 46 25 Req. total capacity at 0.85 SHR 1.8 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade Trade <br /> Model 25HBC524AO0300 Cond 25HBC524AO0300 <br /> AHRI ref 9154943 Coil FB4CNP025L <br /> AHRI ref 9154943 <br /> Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER <br /> Heating input Sensible cooling 20400 Btuh <br /> Heating output 24000 Btuh @ 470F Latent cooling 3600 Btuh <br /> Temperature rise 27 OF Total cooling 24000 Btuh <br /> Actual air flow 800 cfm Actual air flow 800 cfm <br /> Air flow factor 0.070 cfm/Btuh Air flow factor 0.044 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.85 <br /> Capacity balance point= 14 OF <br /> Backup: <br /> Input= 3 kW, Output= 11787 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -Fk- 2018-Oct-01 08:01:26 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> ACCA ...\2575B sf ADS template vW 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: W <br />