Laserfiche WebLink
Manual S Compliance Report Job: 2575B1 sf ADS Cairiervw <br /> Date: 1011/2018 <br /> lower floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> I <br /> Project Information <br /> For: Lennar Homes <br /> I <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 11824 Btuh Entering coil DB: 75.8°F <br /> Outdoor design WB: 77.3°F Latent gain: 1382 Btuh Entering coil WB: 62.9°F <br /> Indoor design DB: 75.0°F Total gain: 13207 Btuh <br /> Indoor RH: 50% Estimated airflow: 600 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Sensible capacity: 15300 Btuh 129% of load <br /> Latent capacity: 2700 Btuh 195% of load <br /> Total capacity: 18000 Btuh 136% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 17322 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: SpIitASHP <br /> Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L <br /> Actual airflow: 600 cfm <br /> Output capacity: 13453 Btuh 78% of load Capacity balance: 32 OF <br /> Supplemental heat required: 3869 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 600 cfm <br /> Output capacity: 4.5 kW 88% of load Temp. rise: 50 OF <br /> Meets all requirements of ACCA Manual S. <br /> 8:01:26 <br /> 2018-Oct-01 0 <br /> wrightsoft® Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 <br /> 14CC* ...\25758 sf ADS template VW 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: W <br />