My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20751
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20751
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 9:04:35 AM
Creation date
1/14/2020 9:04:33 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-20751
Building Department - Name
LENNAR HOMES LLC
Address
3312 MOULDEN HOLLOW DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Compliance Report Job: 2575B1 sf ADS Carrier VW <br /> Date: 10/1/2018 <br /> upper floor By: Dave <br /> Bayonet Plumbing Heating and Air <br /> Project • • <br /> For: Lennar Homes <br /> Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.3°F Sensible gain: 18094 Btuh Entering coil DB: 75.6°F <br /> Outdoor design WB: 77.3°F Latent gain: 3099 Btuh Entering coil WB: 62.8°F <br /> Indoor design DB: 75.0°F Total gain: 21192 Btuh <br /> Indoor RH: 50% Estimated airflow: 800 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Sensible capacity: 20400 Btuh 113% of load <br /> Latent capacity: 3600 Btuh 116% of load <br /> Total capacity: 24000 Btuh 113% of load SHR: 85% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 30.8°F Heat loss: 11492 Btuh Entering coil DB: 69.6°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L <br /> Actual airflow: 800 cfm <br /> Output capacity: 24000 Btuh 209% of load Capacity balance: 14 °F <br /> Supplemental heat required: 0 Btuh Economic balance: -99 °F <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 800 cfm <br /> Output capacity: 3.5 kW 103% of load Temp. rise: 50 °F <br /> Meets all requirements of ACCA Manual S. <br /> t -�- wrightsoftm 2018-Oct-01 08:01:26 <br /> Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 <br /> ...\2575B sf ADS template VW 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.