Laserfiche WebLink
PREPARED BY: <br /> 37 O.A. MAX: <br /> A.WIDTH <br /> JEL]BrWEN 1 <br /> s d BUILDING DROPS,INC. <br /> W I N D O IV S. K D O O R S O.A.WIDTH <br /> 398 E.DAMABE BlVO.,STE 338 <br /> 6 1 DANIABEAOI,FL33DD0 <br /> fl 2 xx:J(5541 TB <br /> 5 d <br /> 6 78 <br /> FA%:95dPd4 4 <br /> 73B <br /> wca:ww.w�w,�aemps.mm <br /> DESIGN PRO/SMOOTH PRO FULL LITE <br /> 1 � <br /> NON—IMPACT a <br /> � B Z to on., <br /> Lu <br /> FOR USE IN THE HIGH VELOCITY HURRICANE ZONE(HVHZ) 6 0 5 S z o m <br /> g ACTIVE of �' wJ wLLoo <br /> l� 0 ZtoLL ��3 t.0 =¢ g= <br /> §z: s ACTIVE a �3< O s = O� z z �' <br /> GENERAL NOTES: 3<. s s Z N C) O 0 W m y <br /> �2 <br /> 0 = 0— �O H= C7 <br /> 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT FLORIDA O— M \2 Q <br /> BUILDING CODE(FBC),INCLUDING HVHZAND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: >z <br /> • TAS 202-94 'c Z W <br /> J <br /> W <br /> 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY OR 2X FRAMING AS A MAIN WIND FORCE W Q Lu pra <br /> RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE L LO U= ,lB.I <br /> FOUNDATION 15 THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF a 4 s a T a 9 a d s a 8 9 ' <br /> INSTALLATION. 4 4 4 4 4 4 4 4 4 4 4 d d 4 }N a� <br /> �] TYP.ELEVATION 1 �TYP.ELEVATION 2 F—Lu W` <br /> 3. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR 1 6'A'DOOq HEN;NT 1 sa•000axRcxr "' d <br /> A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED 371/2"MAX. r~ <br /> HEREIN,A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS <br /> DOCUMENT. O.A.WIDTH_--_ <br /> REMARKS BY DATE <br /> 4. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT Add Vent Lite Option GL 5/5/14 <br /> RESISTANCE. Add ADA&Multi-Pt GL 5119114 <br /> S. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS.SEE SHEET 6 FOR GLAZING DETAILS. Add GU Hardware LS /23/1 <br /> 6. FULL LITE APPROVAL COVERS USE OF FRACTIONAL GLAZING,INCLUDING INTERNAL GRID,BLINDS BETWEEN D«uMwns lNE vxovlx xBOxuvsxu <br /> GLASS,DECORATIVE,EXTERNAL AND INTERNAL WROUGHT IRON.RADIUS SHAPED LITES ARE QUALIFIED FOR .._ DnDNESWxxO(xBE AEvgrMlicEo`Inuw�l�iouoq vAgi <br /> 1 ) ."'-I AIrExAww,.DDmoa.wocniwxtprwxcOo ER <br /> 6'-8"DOORS AT DP+/-65 ONLY. Go i —S—6 rxls oocu uaxrAu NorBExMRRDAW <br /> (�W Q e O ItNLLiDA1F0 CENTEtGTbx. <br /> 7. NOTE: AFCO H-497 SILL MEETS WATER INFILTRATION AT WATER TEST PRESSSURE (WTP) OF 9.75 PSF. z 6 LL <br /> REMAINING SILLS NOT HATED FOR WATER INFILTRATION. IF AUTHORITY HAVING JURISDICTION REQUIRES THAT <br /> PRODUCT MEETS THIS REQUIREMENT,PRODUCTSHALL BE USED WHEN INSTALLED AT LOCATION PROTECTED BY 3 Ci OJ �� S F•I�fO ///�� <br /> OVERHANG SUCH THAT OVERHANG(OH)RATIO=OH LENGTH+OH HEIGHT IS 21.0 0? <br /> ACTIVE = v T/1T e <br /> TABLE OF CONTENTS NOTE: ����•EBUn EEC `62 G�``� <br /> 31 TYP.ELEVATION 3 DOORS SHOWN ABOVE MAY BE LEFT <br /> SHEET REVISION SHEET DESCRIPTION \—IJ 6'-B•DDOR WITMfIVnONALVEM IRE OR RIGHT HAND OPERATING DOORS. rev�ugyrMy�` �ILJ�iasr9 <br /> 1 C TYPICAL ELEVATIONS,DESIGN PRESSURES,AND GENERAL NOTES SEESHEEEGFORG NGDETADS <br /> Digitally signed by Hermes F.Norero,P.E. <br /> 2 C TYPICAL ANCHOR LAYOUTS AND NOTES Reason:I am approving this document <br /> MAX.OVERALL DESIGN PRESSURE(PSF) Date:2016.08.2618:4159-"00' <br /> 3 C OPTIONAL 2X BUCK ANCHORING DETAILS NOMINALSIZE MISSILE /I <br /> 4 C VERTICAL ASSEMBLIES CONFIGURATION INSWING OUTSWING IMPACT DATE: 02.05.14 <br /> WIDTH HEIGHT RATING DWG.B : CHK.BY: <br /> 5 C HORIZONTAL ASSEMBLIES POS. NEG: POS. NEG. SSM/TJM MSS <br /> 6 C GLAZING DETAILS X T-0" 6'-8" 6SAB 65' 6SAB 65' NON-IMPACT NTS <br /> SCALE: <br /> 7 C WOODSUBSTRATES X(VENT) T-0" 6'-8" 65AB 65' 65"B 65' NON-IMPACT DWG.p:A010862B <br /> 8 C CONCRETE SUBSTRATES %(RADIUS) 3'-0" 6'-8" 65AS 65B 65"B 65, NOWIMPACf <br /> SHEET: OF10 <br /> 9 C COMPONENTS&BILL OF MATERIALS % T-0" 8'-0" 50A 50 50" I 50 NON-IMPACT <br /> 10 C COMPONENTS A:SEE GENERAL NOTE 7,SHEET 1,FOR WATER INFILTRATION APPROVED SILLS. <br /> B:DESIGN PRESSURE LIMITED TO+/-50 PSF WITH USE OF GU HARDWARE,ITEM#27 <br />