My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-20862
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-20862
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 10:22:39 AM
Creation date
1/14/2020 10:22:38 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
19-20862
Building Department - Name
REED JR,BILLY & CARON A
Address
5754 16TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTALLATION NOTES: PREPARED BY: <br /> 1. ONE(1)INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 1®� <br /> SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S).MAXIMUM ALLOWABLE SHIM BUILDING DROPS,INC. <br /> STACK TO BE 1/41NCH.SHIM WHERE SPACE OF 1/161NCH OR GREATER OCCURS.SHIM(5)SHALL BE CONSTRUCTED 398 E.DANIABFACHBLVD..STE.3M <br /> OF NON-COMPRESSIBLE COMPOSITE OR BETTER. DANIA BEACH,FL 33W4 <br /> PH:(954)399 8478 <br /> 2. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES,INCLUDING BUT NOT LIM ITED TO STUCCO, WEB:PAR:195H.4738 <br /> WAW.bud&m dm . <br /> FOAM,BRICK VENEER,AND SIDING. <br /> 3. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR <br /> HAVE A CORROSION RESISTANT COATING,AND SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR N > N <br /> MANUFACTURER'S INSTALLATION INSTRUCTIONS. 371/2"MAX. Lu <br /> O.A.WIDTH u_ F c m o <br /> 4. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK,DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. 3"TYP. 3"Typ. 0 O p D <br /> EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. C2 C2 <br /> Cl p xlan� <br /> S. FOR 2X STUD CONSTRUCTION,ANCHORING OFTHESE PRODUCTS SHALL BE THE SAME AS FOR 2X BUCK - - a Z 5 a s x <br /> CONCRETE/MASONRY CONSTRUCTION. p a m Y 6 LL <br /> IrIN- <br /> 6. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE <br /> FOLLOWING PROPERTIES: O 2 O <br /> A.WOOD-MINIMUM SPECIFIC GRAVITY OF 0.55. Ea } Z: <br /> B.CONCRETE-MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI.C.GROUT-FILLED GROUT-FILLED CMU-UNIT STRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH OF ec to w w w WD <br /> 2000 PSI AND GROUTCONFORMS TO ASTM C 476,MINIMUM GROUT COMPRESSIVE STRENGTH OF 2000 PSI. .-I = m m v1 K � <br /> 0 <br /> D.HOLLOW BLOCK CMU-UNITSTRENGTH CONFORMS TO ASTM C-90 WITH MINIMUM COMPRESSIVE STRENGTH m.m F WO }F•NL? <br /> OF 2000 PSI. m DC z U i�i <br /> z = g = <br /> C6 Z ax <br /> 8. SEE SHEETS 7 AND 8 FOR MORE DETAILS OF THE INSTALLATION REQUIREMENTS,INCLUDING ANCHOR LOCATIONS, 3 z z z Q Wi <br /> EDGE DISTANCES,EMBEDMENTS,AND SHIM SPACING. ?3 0 < O a <br /> 9. OPTIONALLY,ANCHORS CAN BE PLACED IN NARROW SECTION OF HEAD OR IAMB AS LONG AS MINIMUM O Z N N <br /> EMBEDMENTAND EDGE DISTANCE ARE ACHIEVED. REMARKS BY DATE <br /> Add Vent Lite Option GL S/S/14 <br /> i Add ADA&Multi-Pt GL /19/1 <br /> Add GU Hardware LS /23/16 <br /> ANCHORTABLE <br /> fi'8"DOORS 8'0"DOORS A2 A2 DNc—HOTBELPROPER o BwDINGORPART <br /> ND SIULL NOT BF REPRODUCED IN WHOLE OR PART <br /> WROTEN CONSEMOP BUILDING DROP.W <br /> 1 TYP.ANCHOR LAYOUT ALTFRAT...AOD XNS,NIGNWHDNG.OROD FR <br /> RRINGS TO TI45 DON MENTARENOT PERNBrtEDAND <br /> ANCHOR MIN. MIN. 6'A'6 B'-0'DOO-M. LID—OUREERD1-01. <br /> ANCHOR TYPE SUBSTRATE MAX.O.C. MAX.O.C. Z INVA <br /> SIZE EMBEDMENT DISTANCE <br /> SPACING AT SPACING AT ♦♦�111 L L L 17tI/// <br /> JAMBS JAMBS ♦♦♦\♦�SS F. <br /> NOTE: I <br /> NO ANCHORS REQUIRED ATTHE SILL FOR SINGLE DOORS(X)ONLY. `♦� �� //� <br /> 2X WOOD BUCK ; <br /> WOOD SCREW 430 OR FRAMING 1-1/2" 3/4" 17-1/2" 17.1/4• = �••, - -J. 0 <br /> ITW TAPCON 3/16" CONCRETE/CMU 1.1/4• 2-1/2" 17-1/2" 17-1/4" 7IL- <br /> -D - Tf iT rY <br /> 1-3/8"-CONC. NOTE: �•r QfRI/V <br /> ELCO ULTRACON 1/4" CONCRETE/CMU 1-1/4--CMU 1" 17-1/2" 17-1/4" INACTIVE AND ACTIVE DOOR PANEL i 0, •.- ( P;•�yU <br /> ORIENTATION IS INTERCHANGEABLE. /i/F utx'PE a�° ('jam♦��� <br /> TTW TAPCON 3/16" CONCRETE/CMU 1-1/4• 1" 10" 14-3/8" ���Nyl A E�iao.� % <br /> fBPE[fR.Jgt��.pq <br /> B2 2-49 X 21/2"PFH <br /> SCREWS <br /> DETAIL D2 02.05.14 <br /> 2-u9 X 21/2-PFH TYP.HOPPE/GU DATE: <br /> PFH SCREWS MULTI-POINTSHOOTE LOCATION_-__._ SSMB�Tim CH MSS <br /> • PLATCATION <br /> DETAIL 82 (RH PLATE SHOWN) <br /> TYP.HOPPE/GU D2 SCALE: NTS <br /> MULTI-POINT SHOOT BOLT BOLT. 0T DWG.#:AO10862B <br /> PLATE LOCATION SHEET: OF10 <br /> SILL SECTION VIEW n HEAD SECTION VIEW I� <br /> Z INSWING SHOWN OMWING SIMILAR z INSWING SNDWN OU}SWING SIMILAR 1 <br /> S DETaLBE SEED-2L <br />
The URL can be used to link to this page
Your browser does not support the video tag.