Laserfiche WebLink
d <br /> i <br /> ! �f <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2-. Lots shall be graded to comply with R401:3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk-shall have <br /> expansion material. <br /> 6! All setbacks shall be met. <br /> 7. All.property markers shall be uncovered_ .-and marked at time of first inspection. <br /> 8: All A.D.A. requirements shall be met. <br /> 9. No electric,plumbing,. mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10: All Garages:shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> 11. Appliances shall not be installed in a location where subject to'mechanical-damage unless <br /> protected by approved barriers. M303.4 of the F.B.0 <br /> 12..Water heaters shall comply with section P607.3 of the R.B.C.. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1. <br /> 14: Return air in all bedrooms. F.B.C. M1620:4 <br /> 1.5. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> M. All glazing requirements are to be in accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordant gr e with R311 of the F.B.C. <br /> 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19: Combination-type AFCI breakers are required at all locations requiring an AFCI.type'breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 21 All 2016 N.E.C. Codes will be enforced. <br />