Plan Review C103.2 Mechanical Plans,specifications,and/or calculations provide ❑ 13 ❑ <br /> all information with which compliance can be <br /> determined for the mechanical systems and <br /> equipment and document where exceptions to the <br /> standard are claimed. Load calculations per <br /> acceptable engineering st <br /> Plan Review C103.2 Mechanical Plans,specifications,and/or calculations provide ❑ <br /> all information with which compliance can be <br /> determined for the service water heating systems <br /> and equipment and document where exceptions <br /> to the standard are claimed. Hot water system <br /> sized per manufact <br /> Plan Review C103.2 Interior Lighting Plans,specifications,and/or calculations provide <br /> all information with which compliance can be <br /> determined for the interior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> Information provided shoul <br /> Plan Review C103.2 Exterior Lighting Plans,specifications,and/or calculations provide ❑ ❑ ❑ <br /> all information with which compliance can be <br /> determined for the exterior lighting and electrical <br /> systems and equipment and document where <br /> exceptions to the standard are claimed. <br /> Information provided shoul <br /> Insulation C402.2.5 Envelope Slab edge insulation depth/length.Slab insulation ❑ ❑ ❑ <br /> extending away from building is covered by <br /> pavement or>=10 inches of soil. <br /> Insulation C402.2.6 Project Radiant heating systems panels insulated to ❑ <br /> >=R-3.5 on face opposite space being heated. <br /> HVAC C402.2.6 Mechanical Thermally ineffective panel surfaces of sensible ❑ ❑ ❑ <br /> heating panels have insulation>=R-3.5. <br /> Insulation C402.2.6 Envelope Radiant panels and associated components, ❑ <br /> designed for heat transfer from the panel surfaces <br /> to the occupants or indoor space are insulated <br /> with a minimum of R-3.5. <br /> Air Leakage C402.5.7 Envelope Vestibules are installed on all building entrances. <br /> Doors have self-closing devices. <br /> SYSTEM—SPECIFIC C403.2.12.3 Mechanical Fans have efficiency grade(FEG)>=67.The total ❑ <br /> efficiency of the fan at the design point of <br /> operation—15%of maximum total efficiency of <br /> the fan. <br /> HVAC C403.2.13 Mechanical Unenclosed spaces that are heated use only ❑ <br /> radiant heat. <br /> HVAC C403.2.4.2 Mechanical Each zone equipped with setback controls using ❑ ❑ <br /> automatic time clock or programmable control <br /> system. <br /> SYSTEM—SPECIFIC C403.2.4.4 Mechanical Zone isolation devices and controls installed 11 <br /> where applicable. <br /> SYSTEM—SPECIFIC C403.2.4.7 Mechanical Fault detection and diagnostics installed with ❑ ❑ <br /> air-cooled unitary DX units having economizers. <br /> SYSTEM—SPECIFIC C403.2.5 Mechanical Hot water boilers supplying heat via one-or ❑ <br /> two-pipe systems include outdoor setback control. <br /> HVAC C403.2.6.1 Mechanical Demand control ventilation provided for spaces ❑ <br /> >500 ft2 and>25 people/1000 ft2 occupant <br /> density and served by systems with air side <br /> economizer,auto modulating outside air damper <br /> control,or design airflow>3,000 cfm. <br /> SYSTEM—SPECIFIC C403.4.1.1 Mechanical Hydronic and multizone HVAC system controls ❑ ❑ ❑ <br /> areVAV fans driven by mechanical or electrical <br /> variable speed drive per Table C403.4.1.1. <br /> SYSTEM—SPECIFIC C403.4.1.3 Mechanical Reset static pressure setpoint for DDC controlled 13 ❑ <br /> VAV boxes reporting to central controller based on <br /> the zones requiring the most pressure. <br /> SYSTEM—SPECIFIC C403.4.2 Mechanical Temperature reset by representative building <br /> loads in pumping systems for chiller and boiler <br /> systems>500,000 Btu/h. <br /> EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option <br /> 10/5/2018 Page 10 of 22 <br />