My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21343
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21343
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/13/2020 1:03:49 PM
Creation date
4/13/2020 1:03:30 PM
Metadata
Fields
Template:
Building Department
Company Name
BAHR'S PROPANE GASE & A/C
Building Department - Doc Type
Permit
Permit #
19-21343
Building Department - Name
BAHR'S PROPANE GAS & A/C
Address
3708 COPELAND DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Air Leakage C402.5.8 Envelope Recessed luminaires in thermal envelope to limit ❑ <br /> infiltration and be IC rated and labeled.Seal <br /> between interior finish and luminaire housing. <br /> HVAC C403.2.1 Mechanical HVAC systems and equipment design loads ❑ 13 ❑ <br /> calculated in accordance with <br /> ANSI/ASHRAE/ACCA Standard 183 or by an <br /> approved equivalent computational procedure <br /> SYSTEM—SPECIFIC C403.2.10 Mechanical HVAC piping insulation thickness. Where piping ❑ ❑ <br /> is installed in or under a slab,verification may <br /> need to occur during Foundation Inspection. <br /> HVAC C403.2.3 Mechanical HVAC equipment efficiency verified. 0 0 ❑ <br /> SYSTEM—SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16 in.by 42 in. <br /> labeled for replacement only as per Footnote b to <br /> Table C403.2.3(3). <br /> SYSTEM—SPECIFIC C403.2.4.1 Mechanical Heating and cooling to each zone is controlled by ❑ ❑ <br /> a thermostat control. Minimum one humidity <br /> control device per installed <br /> humidification/dehumidification system. <br /> SYSTEM—SPECIFIC C403.2.4.1.1 Mechanical Heat pump controls prevent supplemental electric <br /> resistance heat from coming on when not needed. <br /> HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 A°F deadband. ❑ ❑ <br /> HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 A°F deadband. <br /> HVAC C403.2.4.1.3 Mechanical Temperature controls have setpoint overlap <br /> restrictions. <br /> HVAC C403.2.4.2.1, Mechanical Automatic Controls:Setback to 55°F(heat)and 0 ❑ <br /> C403.2.4.2.2 85°F(cool);7-day clock,2-hour occupant <br /> override,10-hour backup <br /> SYSTEM—SPECIFIC C403.2.4.2.3 Mechanical Systems include optimum start controls. <br /> HVAC C403.2.4.5, Mechanical Snow/ice melting system sensors for future <br /> C403.2.4.6 connection to controls.Freeze protection systems <br /> have automatic controls installed. <br /> HVAC C403.2.6.2 Mechanical Enclosed parking garage ventilation has ❑ ❑ <br /> automatic contaminant detection and capacity to <br /> stage or modulate fans to 50%or less of design <br /> capacity. <br /> HVAC C403.2.9 Mechanical HVAC ducts and plenums insulated. Where ducts <br /> or plenums are installed in or under a slab, <br /> verification may need to occur during Foundation <br /> Inspection. <br /> SYSTEM—SPECIFIC C403.2.9.1.3 Mechanical Ductwork operating>3 in.water column requires <br /> air leakage testing. <br /> SYSTEM—SPECIFIC C403.4.1.2 Mechanical VAV fans have static pressure sensors located so 13 ❑ ❑ <br /> controller setpoint<=1.2 w.c.. <br /> SYSTEM—SPECIFIC C403.4.2.2 Mechanical Two-pipe hydronic systems using a common <br /> distribution system have controls to allow a <br /> deadband>=15°F,allow operation in one mode <br /> for at least 4 hrs before changeover,and have <br /> rest controls to limit heating and cooling supply <br /> temperature to<=30 OF. <br /> SYSTEM—SPECIFIC C403.4.2.3.3 Mechanical Two-position automatic valve interlocked to shut ❑ El El <br /> off water flow when hydronic heat pump with <br /> pumping system>10 hp is off. <br /> SYSTEM—SPECIFIC C403.4.4.5, Mechanical Zone controls can limit simultaneous heating and ❑ ❑ ❑ <br /> C403.4.4.5.1-4 cooling and sequence heating and cooling to each <br /> zone. <br /> SYSTEM—SPECIFIC C403.4.5 Mechanical Condenser heat recovery system that can heat <br /> water to 850F or provide 60%of peak heat <br /> rejection is installed for preheating of service hot <br /> water. <br /> SYSTEM—SPECIFIC C403.4.6 Mechanical Hot gas bypass limited to: ❑ <br /> <=240 kBtu/h-50%capacity, <br /> >240 kBtu/h -25%capacity <br /> SYSTEM—SPECIFIC C404.3 Mechanical Heat traps installed on non-circulating storage ❑ ❑ <br /> water tanks. <br /> EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 <br /> Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option <br /> 10/5/2018 Page 13 of 22 <br />
The URL can be used to link to this page
Your browser does not support the video tag.