My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21388
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21388
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2020 6:09:50 AM
Creation date
4/15/2020 6:09:31 AM
Metadata
Fields
Template:
Building Department
Company Name
ROSE RADIOLOGY
Building Department - Doc Type
Permit
Permit #
19-21388
Building Department - Name
SPK TAMPA LLC
Address
6900 GALL BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�PTRRINI-rYJERD <br /> 16. For adhered membrane systems,side laps shall be minimum 2-inch wide sealed with min.1.5-inch heat weld. Unless otherwise noted,membrane adhesive application rates are as follows: <br /> Membrane Adhesive Method Rate <br /> Mule-Hide TPO-c Mule-Hide TPO-c Bonding Adhesive(TPO-c BA) Contact(both sides) 60 ft2/gal <br /> Mule-Hide TPO-c Aqua Base 120 BA Contact(both sides) 120 ft2/gal <br /> Mule-Hide TPO-c Fleece Back Aqua Base 120 BA Wet lay(substrate) 120 ft2/gal <br /> Mule-Hide TPO-c Fleece Back Mule-Hide Helix®Low-Rise Adhesive(HELIX) Wet lay(substrate) FULL=continuous ribbons,maximum 4-inch o.c. <br /> 17. For membrane systems attached using TPO 10-inch Pressure-Sensitive RUSS,the underside of the membrane which comes in contact with the tape shall be primed with HP-250 Primer. The membrane shall be <br /> secured by placing the primed portion onto the tape portion of the TPO 10-inch Pressure-Sensitive RUSS and roll with a steel hand roller to ensure contact. <br /> 18. For bonded membrane systems,unless otherwise noted,reference to"Mule-Hide TPO-c"membrane below also includes"Mule-Hide TPO-c EXTRA". <br /> 19. Vapor barrier options for use over structural concrete deck followed by adhesive-applied insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs.those in <br /> Table 3A applies. <br /> VAPOR BARRIER OPTIONS;STRUCTURAL CONCRETE DECK;FOLLOWED BY ADHESIVE-APPLIED INSULATION PER TABLE 3A: <br /> Option# Primer Vapor Barrier <br /> Type Application Insulation Adhesive MDP(psf) <br /> VB-1. Carlisle CAV-GRIP Primer F5T"Air&Vapor Barrier or Carlisle VapAir Seal 725TR Self-adhering HELIX(RIBBON,12-inch D.C.) -97.5 <br /> VB-2. ASTM D41 Carlisle SureMB 90TG Base or SureMB 120 TG Poly Base Torch-applied HELIX(RIBBON,12-inch o.c.) -97.5 <br /> VB-3. ASTM D41 Carlisle SureMB 90 Base or SureMB 120 Poly Base Hot-asphalt HELIX(RIBBON,12-inch o.c.) -97.5 <br /> 20. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. <br /> Exterior Research and Design,I.I.C.d/b/a Trinity I ERD Evaluation Report M15060.06.09-R5 for FL32772-RS <br /> Certificate of Authorization#9503 CH EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 <br /> Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 3 of 27 <br />
The URL can be used to link to this page
Your browser does not support the video tag.