TRINIIY j ERD <br /> TABLE 2B: STEEL or STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER <br /> System Deck Base Insulation Layer Roof Cover(Note 16)Top Insulation Layer MOP <br /> No. (Note 1) Type Fasteners Attach (psf) - <br /> MULE-HIDE TPO-c APPLICATIONS: <br /> SC-16 Min.22 ga.,type B,Grade 33 steel Min.1.5"thick,one or more layers, Min 7/16"APA or TECO rated OSB Trufast SIP LD 1 per 3.2 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua -37.5* <br /> any combination,loose laid Fasteners Base 120 BA <br /> SC-17 <br /> Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.1-inch Poly ISO 2,ACFoam Note 2 1 per 1.6 II p Mule-Hide TPO-c/TPO-c BA or Aqua 37.5* <br /> min.2,500 psi structural concrete combination,loose laid or ENRGY 3 ft2 Base 120 BA <br /> SC-18 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min.0.5-inch H-Shield HD Note 2 1 per 2.67 ft2 Mule-Hide TPO-c/TPO-c BA -37.5* <br /> min.2,500 psi structural concrete layers,any combination,loose laid <br /> SC-19 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.25-inch SECUROCK Gypsum- Note 2 1 per 2.67 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua 37.5* <br /> min.2,500 psi structural concrete layers,any combination,loose laid Fiber Roof Board Base 120 BA <br /> SC-20 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.50-inch SECUROCK Gypsum- Note 2 1 per 3.2 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua -45.0* <br /> min.2,500 psi structural concrete layers,any combination,loose laid Fiber Roof Board Base 120 BA <br /> SC-21 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.625-inch SECUROCK Note 2 1 per 4.0 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua -45.0* <br /> min.2,500 psi structural concrete layers,any combination,loose laid Gypsum-Fiber Roof Board Base 120 BA <br /> SC-22 Min.22 ga.,type B,Grade 33 steel Min.1.5"thick,one or more layers, Min 7/16"APA or TECO rated OSB Trufast SIP LD 1 per 2.67 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua -45.0* <br /> any combination,loose laid Fasteners Base 120 BA <br /> SC-23 Min.22 ga.,type B,Grade 33 steel or One or more layers,any combination, Min 7/16"APA or TECO rated OSB Note 2 1 per 3.6 ft2 Mule-Hide TPO-c/TPO-c BA or Aqua -45.0* <br /> min.2,500 psi structural concrete loose laid Base 120 BA <br /> SC 24 <br /> Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.1-inch Poly ISO 1,H-Shield,H- Note 2 1 per p 1.6 Mule-Hide TPO-c/TPO-c BA or Aqua 45.0* <br /> min.2,500 psi structural concrete combination,loose laid Shield CG ft2 Base 120 BA <br /> Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min.1.5-inch ACFoam II,Poly ISO 2 Mule-Hide TPO-c/TPO-c BA or Aqua <br /> SC-25 min.2,500 psi structural concrete combination,loose laid 2,H-Shield,Poly ISO 1,H-Shield Note 2 1 per 2.0 ft Base 120 BA -45.0 <br /> CG,EN RGY 3 <br /> Min.22 ga., ,Grade 33 steel or Min.2.0-inch ACFoam II,Poly ISO <br /> SC-26 type B (Optional)One or more layers,any 2,H-Shield,Poly ISO 1,H-Shield Note 2 1 per 4.0 ft2 Base <br /> Mule-Hide TPO-c/TPO-c BA or Aqua -45.0* <br /> CG,ENRGY 3 Bas <br /> min.2,500 psi structural concrete combination,loose laid e 120 BA <br /> SC-27 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min.0.5-inch H-Shield HD Note 2 1 per 2.0 ft2 Mule-Hide TPO-c/TPO-c BA - -45.0* <br /> min.2,500 psi structural concrete layers,any combination,loose laid <br /> SC-28 Min.22 ga.,type B,Grade 33 steel or Min.1.5"thick,one or more layers, Min 7/16"APA or TECO rated OSB Note 2 1 per 1.9 ft2 Mule-Hide TPO-c/Aqua Base 120 -52.5 <br /> min.2,500 psi structural concrete any combination,loose laid BA <br /> SC-29 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more <br /> min.2,500 psi structural concrete layers,any combination,loose laid Min 0.5-inch Dens Deck Prime Note 2 1 per 1.6 ft2 Mule-Hide TPO c/TPO-c BA 60.0 <br /> Min.22 ga.,type B,Grade 33 steel or Min.1.5"thick,one or more layers, <br /> SC-30 min.2,500 psi structural concrete any combination,loose laid Min 7/16"APA or TECO rated OSB Note 2 1 per 1.9 ft2 Mule-Hide TPO-c/TPO-c BA 75.0 <br /> Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min 2.0-inch ACFoam II,Poly ISO 1, <br /> SC-31 min.2,500 psi structural concrete combination,loose laid Poly ISO 2,H-Shield,H-Shield CG, Note 2 1 per 1.6 ft2 Mule-Hide TPO-c/TPO-c BA -75.0 <br /> ENRGY3 <br /> Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report M15060.06.09-R5 for FL12772-RS <br /> Certificate of Authorization#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 <br /> Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 8 of 27 <br />