�VTRRINITYIERD <br /> TABLE 2B: STEEL or STRUCTURAL CONCRETE DECKS-NEW CONSTRUCTION,REROOF(Tear-Off)or RECOVER <br /> SYSTEM TYPE C-1: MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER <br /> System Deck Top Insulation Layer MOP <br /> Base Insulation Layer Roof Cover(Note 16) <br /> No. (Note 1) Type Fasteners Attach (psf) <br /> SC-32 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 0.5-inch SECUROCK Gypsum- <br /> min.2,500 psi structural concrete layers,any combination,loose laid Fiber Roof Board Note 2 i per 1.6 ftZ Mule Hide TPO-c/TPO-c BA 82.5 <br /> SC-33 Min.22 ga.,type B,Grade 33 steel or Min.1.5-inch thick,one or more Min 7/16-inch APA or TECO rated <br /> min.2,500 psi structural concrete layers,any combination,loose laid OSB Note 2 1 per 1 ftZ Mule-Hide TPO-c/TPO-c BA 97.5 <br /> Min.20 ga.,type B,Grade 33 steel or (Optional)Min.1.5-inch thick,one or Min.0.625-inch SECUROCK <br /> SC-34 min.2,500 psi structural concrete more layers,any combination,loose Gypsum-Fiber Roof Board Note 2 1 per 1.33 ftZ Mule-Hide TPO-c/TPO-C BA -112.5 <br /> laid <br /> SC-35 Min.18 ga.,type B,Grade 33 steel or Min.2-inch thick,one or more layers, Min.0.5-inch SECUROCK Gypsum- Note 2 1 per 1.33 ft2 Mule-Hide TPO-c/TPO-c BA -112.5 <br /> min.2,500 psi structural concrete any combination,loose laid Fiber Roof Board <br /> SC-36 Min.22 ga.,type B,Grade 33 steel or (Optional)One or more layers,any Min 2-inch H-Shield CG Note 2 1 per 1 ftZ Mule-Hide TPO-c/TPO-c BA -120.0 <br /> min.2,500 psi structural concrete combination,loose laid <br /> MULE-HIDE SA-TPO APPLICATIONS: <br /> Min.22 ga.,type B,Grade 33 steel or (Optional for Recover)Min.1.5-inch <br /> SC-37 min.2,500 psi structural concrete thick,one or more layers,any Min.2-inch Insulfoam SP Note 2 1 per 2.7 ftZ Mule-Hide SA-TPO,self-adhered -30.0* <br /> combination,loose laid <br /> Min.22 ga.,type B,Grade 33 steel or (Optional for Recover)Min.1.5-inch <br /> SC-38 min.2,500 psi structural concrete thick,one or more layers,any Min.2-inch Insulfoam SP Note 2 1 per 2.0 ftZ Mule-Hide SA-TPO,self-adhered -45.0* <br /> combination,loose laid <br /> (Optional for Recover)Min.1.5-inch <br /> Min.0.25-inch Dens Deck Prime or <br /> Min.22 ga.,type B,Grade 33 steel or SECUROCK Gypsum-Fiber Roof <br /> SC-39 min.2,500 psi structural concrete thick,one or more layers,any Board or min 7/16-inch APA or Note 2 1 per 2.0 ft� Mule-Hide SA-TPO,self-adhered 45.0` <br /> combination,loose laid <br /> TECO rated OSB <br /> Min.22 ga.,type B,Grade 33 steel or (Optional)Min.1.5-inch thick,one or Min.1.5-inch Poly ISO 1,H-Shield, <br /> SC-40 min.2,500 psi structural concrete more layers,any combination,loose Polyiso HP-H,SecurShield,H-Shield Note 2 1 per 2.0 ft2 Mule-Hide SA-TPO,self-adhered -45.0* <br /> laid CG <br /> Min.22 ga.,type B,Grade 33 steel or (Optional)Min.1.5-inch thick,one or Min.2.0-inch Poly ISO 1,H-Shield, <br /> SC-41 min.2,500 psi structural concrete more layers,any combination,loose Polyiso HP-H,SecurShield,H-Shield Note 2 1 per 1.6 ftZ Mule-Hide SA-TPO,self-adhered -60.0 <br /> laid CG <br /> Exterior Research and Design,LLC.d/b/a Trinity ERD Evaluation Report M15060.06.09-R5 for FL12772-RS <br /> Certificate of Authorization#9503 6T"EDITION(2017)FBC NON-HVHZ EVALUATION Revision 5:09/11/2017 <br /> Prepared by: Robert Nieminen,PE-59166 Mule-Hide TPO-c Single Ply Roof Systems;(608)365-3111 Appendix 1,Page 9 of 27 <br />