Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21494
Building Department - Name
D.R. HORTON
Address
7018 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Manual S Com "liance'Re ort Job' <br /> - wrightsoft® p • Date:. <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: laze Call <br /> 5907'Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399"• License:CA'C033669 <br /> PrQjectJhf6fmafion <br /> For: DR Horton <br /> Lot 13 Blk 7 Silverado, Zephyrhills, FL <br /> PilJolin. fulpMelit <br /> Design Conditions - <br /> Outdoor design DB: 91.2°F Sensible gain:, 20971 Btuh Entering coil DB: 75.8°F <br /> Outdoor.design WB: 77.1 OF Latent gain: 3647 Btuh Entering coil WB: 62.90F <br /> Indoor design DB: 75.0°F Total gain:_... 24618 Btuh <br /> Indoor RH: 50% Estimated airflow: 1000 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> -Manufacturer: Carrier Model: CH14NB030+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Sensible capacity:. 23045. Btuh 1100%of load <br /> Latent capacity: 4228 Btuh 116%of load <br /> Total capacity:, 27273 Btuh 111%of load SHR: '84% . <br /> • • • <br /> Design Conditions. <br /> Outdoor design DB:' 40.0°F Heat loss: 21992 Btuh Ertering coil DB: 69.7°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions' <br /> Equipment type: ..Split ASHP <br /> Manufacturer: Carrier Model: CH14NB030+FB4CNP030 <br /> Actual airflow: 1000 cfm <br /> Output capacity: 25616 Btuh 116%of load Capacity balance: 33 OF. <br /> Supplemental heat required:: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1000 cfm <br /> Output capacity: .6.6 kW 1020%of load Temp. rise: .20 OF <br /> Meets are all requirements of ACCA Manual S." <br /> 1 Wrl hlkSoft' 2019-Mar-1411:16:56' <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=MJ8 House Front.faces: W <br />