Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21494
Building Department - Name
D.R. HORTON
Address
7018 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Load Short Form "Job: ; <br /> wlrightsoft - . Date:' <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: ysascar <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669. <br /> Project • • <br /> For: DR Horton <br /> Lot 13 8I0 Silverado, 2ephyrhills, FL <br /> Desi• • • <br /> Htg Clg Infiltration <br /> Outside db(OF) 40 91 . Method Simplified <br /> Inside db(OF) 70 75 Construction quality Semi-tight <br /> Design TD (°F) 30 16" Fireplaces . 0 <br /> Daily range - L <br /> Inside.humidity (%) 50 50 <br /> Moisture difference(gr/lb) 26 54 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER. <br /> Model CH14NBO30 Cond CH14NBO30 <br /> AHRI ref Cail FB4CNP030 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER <br /> Heating input Sensible cooling .22500 Btuh <br /> Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh <br /> Temperature rise 27 OF Total cooling 30000 Btuh <br /> Actual air flow 1000 cfm Actual air flow 1000 cfm <br /> Air flow factor 0.045 -cfm/Btuh Air flow.factor 0.048 cfm/Btuh <br /> Static pressure 0.45 in H2O Static pressure 0.45 in H2O <br /> Space thermostat Load sensible heat ratio. 0.85 <br /> Capacity balance point=33 OF <br /> Backup: <br /> Input=7 kW, —Output=22477 Btuh, 100 AFUE <br /> ROOM NAME Area Htg load Clg load' Htg AVF Clg AVF <br /> (ft2) (Btuh) (Btuh) '(cfm) (cfm) <br /> m.bed 194 3361 3343 153 159 <br /> living 252 3018 3872 137 - 185 <br /> kitchen/dining 367 4532 4197 206 200 <br /> bed 3 149 1484 1162 67 55 <br /> bath 2 55 634 298 29 14 <br /> bed 2 158 3573 3517 162 168- <br /> wc 21 0 0 0 0 <br /> m bath 114 1350 712 61 34 <br /> wic 66 87 129 4 6 <br /> laundry. 39 45 681 2 32 <br /> bed 4 -169 1976 1407' 90 67 <br /> a/c 18 0 0 0 0 <br /> .foyer : 218 _ 1934 1654 88. 79 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wrl fE 20i9-Mar-14 I� �htso � Right-Soite�Universal 2017 17.0.21 RSU25554 - '. Page 1 <br /> ...ightsoft Files\Express homes\Cali 4EBB 1828.rup Cala=MJ8 House Front faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.