Laserfiche WebLink
D <br /> Q <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered_ site plan. <br /> 2. Lots shall be-graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required.if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5-. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 1. All.property markers shall be uncovered and marked at time of first inspection. <br /> 8.. All A.D.A.requirements shall be met: <br /> 9. No electric,.plumbing, mechanical,or framing shall be:covered without an inspection and <br /> approval first. <br /> 10: All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 1.1. Appliances shall not be installed in a location where subject.to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the F:B.C: <br /> 13.- Foundation supports for A/.0 units-shall be raised at least 3" above finished grade. M1308.1 <br /> 14.. Return air in all bedrooms: F.B.C. M1620.14 <br /> 1.5. Smoke detectors are to be installed in accordance with R313-.1 of the F.B.C. <br /> 16:All glazing requirements are to be'in' accordance'with R308.4 of the F.B.C: <br /> 17. All means of egress are.to be in accordance with R311 of the F.B.C. <br /> 18: "Green gypsum.board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AM type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C: <br /> 21. All plumbing, -mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 21 All 2016 N.E.C. Codes will be enforced. <br />