My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21503
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21503
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2020 6:53:03 AM
Creation date
4/15/2020 6:52:36 AM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
19-21503
Building Department - Name
CITY OF ZEPHYRHILLS (POLICE DEPT)
Address
6118 8TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
instruments and testing, adjusting and balancing, except as otherwise indicated. <br /> C. The final result of balancing shall be to provide uniform air temperatures within a 2° F spread in <br /> the conditioned space at peak load conditions. All air flows shall be within —5/+10% of design air <br /> flows. <br /> D. In the event of dispute with regard to test results, the Owner or Project Engineer may choose to <br /> provide verification of test and balance reports, and such verification shall be by a second <br /> independent agency selected by the Project Engineer or the Owner. Reports found to be <br /> inaccurate will be disallowed, and the test and balance firm will be required to repeat operations <br /> under the supervision of the second independent agency until accurate reports are completed <br /> and agreed upon. The cost of initial test and balance work will be borne by the Owner. The cost <br /> of verification test and balance work shall be borne by the Owner or Contractor or Project <br /> Architect/Engineer (whichever demanded the second opinion). If the original test and balance <br /> reports are found inaccurate and subsequent costs of supervision are necessary in order to <br /> secure acceptable reports, such will be borne by the original test and balance firm. <br /> 1.5 SUBMITTALS <br /> A. Submit five (5) certified test reports signed by Test and Balance Supervisor who performed <br /> testing and balancing work to Engineer and to the Architect seven days prior to substantial <br /> completion inspection. <br /> 1. Include identification and types of instruments used and their most recent end tolerance <br /> calibration sheets with submission of final test report. Calibration shall be within six <br /> months of the date of equipment used on this project. <br /> 2. Report shall include a schematic diagram indication the system tested and the device <br /> number of the report correlated to the actual device of the system. Include in the <br /> "NOTES" Section of the report, the actual serial number of the hood used for air flow <br /> measurements. <br /> B. Maintenance Data: Include a copy of certified test and balance report in the operation and <br /> maintenance manual. <br /> 1.6 JOB CONDITIONS <br /> A. Do not proceed with testing, adjusting and balancing work until work has been completed and is <br /> operable. Ensure that there is no latent residual work still to be completed. <br /> B. Do not proceed until work scheduled for testing, adjusting and balancing is clean and free from <br /> debris, dirt and discarded building materials. <br /> 1.7 GUARANTEE <br /> A. The test and balance firm shall include extended services for six months after completion of test <br /> and balance work, during which time the Project Architect/ Engineer and/or Owner, at their <br /> discretion, may request a recheck or resetting of any piece of equipment listed in the test report <br /> believed to not be performing properly. The Contractor shall assist in this extended service. <br /> B. The test and balance firm shall provide technicians to assist in making any tests required. Should <br /> the system be found to not work properly any time during the first year of operation, it shall then <br /> be required to be rebalanced. <br /> C. The test and balance agency shall provide to the Architect five (5) copies of a certified statement <br /> that the HVAC systems have been balanced to optimum performance capabilities in accordance <br /> CEA#18010 TESTING,ADJUSTING AND BALANCING 23 05 93-3 <br /> COPYRIGHT©2018 CONSULTING ENGINEERING ASSOCIATES, INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.