My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21503
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21503
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/15/2020 6:53:03 AM
Creation date
4/15/2020 6:52:36 AM
Metadata
Fields
Template:
Building Department
Company Name
CITY OF ZEPHYRHILLS
Building Department - Doc Type
Permit
Permit #
19-21503
Building Department - Name
CITY OF ZEPHYRHILLS (POLICE DEPT)
Address
6118 8TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
61
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. Three (3) row liquid reheat coil. <br /> 4. Stainless steel sloped drain pan. <br /> 5. Corrosion resistant construction withstanding 500 hour(minimum)salt spray test. <br /> 6. Full capacity receiver. <br /> 7. Meet or exceed scheduled EER's at design conditions. <br /> 8. Insulation as specified. <br /> 9. Compressor operation to 58° F DB. <br /> G. All safety and operational controls shall be factory wired. <br /> H. Safety and operational control features: <br /> 1. Internal compressor over temperature protection. <br /> 2. Crankcase heaters. <br /> 3. Individual motor overcurrent protection. <br /> 4. High pressure cutout. <br /> 5. Low pressure cutout. <br /> 6. Anti-recycle timer(5 minute). <br /> 7. Phase failure and low voltage protection. <br /> I. Refrigerant piping: Copper tubing inside, 3/4" and smaller: type ACR, soft appealed temper; cast <br /> copper-alloy fittings for flared copper tubes; flared joints. <br /> J. Copper tubing outside, all sizes: Type ACR, hard-drawn temper tubing; wrought-copper, solder- <br /> joint fittings; brazed joints. <br /> K. Brazing material: Silver solder bearing at least 15% silver; Sil Fos. <br /> 2.2 INDOOR UNIT WITH REMOTE CONDENSER <br /> A. Modes of Operation (Variable Reheat): <br /> 1. In the dehumidification process, latent heat is transferred from the outside air to the <br /> refrigerant as it passes through the evaporator coil. As the air is cooled below its dew- <br /> point, moisture condenses on the evaporator coil. The latent heat captured by this <br /> process, along with the power consumption of the compressor, is absorbed by the <br /> mechanical refrigeration system. This energy is returned to the air stream via the reheat <br /> coil, resulting in lower relative humidity of the leaving air. <br /> 2. The energy recovered is split between the hot gas reheat condenser and a full-size, <br /> outdoor air-cooled condenser or optional water condenser. Hot gas reheat is varied <br /> automatically by a modulating valve controlled by a microprocessor controller, so that the <br /> user's system leaving air temperature set-point is maintained to within + or — 2.0° F. <br /> During the heating season, the compressor shall be locked out below a 550 F entering air <br /> dew point. When the unit is provided with a full cooling option, on a call for cooling from <br /> an optional space thermostat, the unit will disengage the hot gas reheat. <br /> B. Unit Description <br /> 1. Unit Enclosure: A 14-gauge galvanized base panel shall be incorporated in all units. The <br /> unit shall be a minimum of 18-gauge galvanized panels. Supports shall be constructed of <br /> 14-gauge galvanized steel. Removable panels shall be provided to allow easy access to <br /> all internal parts and components. The electrical control box and switch panel shall be <br /> enclosed in a separate compartment, complete with a hinged door. Single Side Service <br /> Access — The unit shall be designed for complete access for service and maintenance <br /> from one side only. The units will require side access for easy removal of the filters. See <br /> mechanical drawings for access required. <br /> CEA#18010 100% OUTSIDE AIR UNITS 23 75 33 -2 <br /> COPYRIGHT©2018 CONSULTING ENGINEERING ASSOCIATES, INC. <br />