Laserfiche WebLink
ONEMOjetc. <br /> 's• • i• • <br /> Wood or Slate or <br /> Asphalt Nail-On7rile <br /> m On Compost#e <br /> Undertayment Shingles Tile Metal Shakes& Composite <br /> Shingles Slate <br /> Lastobond Eaves Protection Sheet/ = <br /> Lastobond 195 Yes No . IVo,. Na Yes Yes <br /> Lastobond ECO /RESISTO L81236, <br /> Grip-Rite Eave&Valley Protector/ Yes. No: .' . .No Nb Yes V Yes <br /> RESISTO LB1244 <br /> Lastobond Smooth Seal HT Yes ,IVo No Yes Yes .Yes.. . <br /> Colphene FR GR Yes Yes 'Yes N0' Yes Yes, <br /> See 5.5.1 <br /> 5.5.1 "Foam-On Tile"is limited to use of following Approved tile adhesives/underlayment combinations. <br /> Adhesive Florida Product Approval Underlayments <br /> Dow TileBond' FL22525 Lastobond TU HT <br /> ICP Adhesives PolysetO AH-160 FL6332 Lastobond TU HT or Colphene FR GR <br /> 5.6 Allowable Substrates: <br /> 5.6.1 Direct-Bond to Deck: <br /> Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, <br /> Enviro5hietd, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO <br /> LB1236,Grip-Rite Eave&Valley Protector,RESISTO LB1244 or Lastobond Smooth Seal HT applied to: <br /> ➢ Plywood;A5TM D41 primed plywood;OSB;ASTM D41 primed OSB;Southern Yellow Pine;ASTM D41 primed <br /> Southern Yellow Pine;ASTM D41 primed structural concrete. <br /> Colphene FR GR applied to: <br /> ➢ Plywood;ASTM D41 primed plywood;ASTM D41 primed structural concrete, <br /> Note: <br /> ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming <br /> with Elastocot Stick or Elastocoi 600c if the final roof cover is not slated for installation within 24 hours. <br /> ➢ Soprema requires tongue-and-groove board decking be covered with plywood or OSB prior to installation of <br /> the self-adhering underlayment. <br /> 5.6.2 Bond-to-Insulation: <br /> Lastobond Shield,Lastobond Pro HT-N,RESISTO SA SMOOTH PLY 40,Lastobond Shield HT,Lastobond Pro HT-S, <br /> EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO <br /> LB1236, Grip-Rite Eave &-Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR <br /> applied to: <br /> ➢ Dens Deck Prime;SECUROCK Gypsum-Fiber Roof Board. <br /> For installation under mechanically_attached prepared roof coverings, insulation shall be attached per minimum <br /> requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam-on <br /> tile systems(Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional <br /> and installed based on testing of the insulation/underlayment system in accordance with FM 4474,Appendix D, <br /> Testing Application Standard TAS 114,Appendix J or UL1807. <br /> i Refer to Tile Manufocturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. <br /> NEMO ETC,LLC Evaluation Report S18010.06.09-R12 <br /> Certificate of Authorization#32455 IV"EDITION(2017)FBC NON-HVHZ EVALUATION FL2569-R14 <br /> Soprema Roof Underlayments Revision 12:02/12/2018 <br /> Page 4 of 8 <br />