Laserfiche WebLink
21 Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots.shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation-for lint water pipe with a.minimum thermal resistance-(R-value) of R-3 shall be applied to the <br /> following: <br /> Piping 31, inch (19.1 mm)and larger in nominal.diameter.. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space: <br /> Piping from the water heater to.a distribution manifold. <br /> Piping located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems: <br /> 25. Blower door test shall be provided before C.O: <br /> 26.A cony of the energy cacls shall be with-permit at all times: <br /> 27 Conn of finqtihsqhgdoh rep6it-shall be provided with Permit before fnab <br /> 28.No fence, Pool or screen enclosure .is issued with ahis pern:i <br /> F.F.E:-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6a'Edition <br /> R.O.W:-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />