Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: 1551 B1 sf ADS Carrier VW Builder Name: Lennar Homes 0323 <br /> Street: 39684 Dawson Chase Drive Permit office: City of Zephyrhills <br /> City,State,Zip: ,FL, Permit Number: rjj 0 <br /> Owner: Lennar Homes Jurisdiction: 611600 <br /> Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) <br /> 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 <br /> b.Frame-Wood,Adjacent R=11.0 321.33 ft2 <br /> 3. Number of units,if multiple family 1 c.N/A R= ft2 <br /> 4. Number of Bedrooms 3 d.N/A R= ft2 <br /> 10.Ceiling Types (1555.0 sqft.) Insulation Area <br /> 5. Is this a worst case? Yes <br /> a.Under Attic(Vented) R=30.0 1555.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 <br /> Conditioned floor area below grade(ftZ) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 <br /> a. U-Factor: Dbl,U=0.33 55.00 ft2 <br /> SHGC: SHGC=0.23 <br /> b. U-Factor: Dbl,U=0.55 33.33 ft2 12.Cooling systems kBtu/hr., Efficiency <br /> -SHGC: SHGC=0.34 a.Central Unit 24.0 SEER:15.50 <br /> c. U-Factor: Dbl,U=0.33 16.00 ft2 <br /> SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.319 ft. <br /> Area Weighted Average SHGC: 0.262 14.Hot water systems- <br /> 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons <br /> a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 EF:0.950 <br /> 9 b. Conservation features <br /> b.N/A R= ft2 None <br /> c.N/A R= ft2 15.Credits Pstat <br /> Glass/Floor Area: 0.067 Total Proposed Modified Loads: 49.77 PASS <br /> Total Baseline Loads: 50.85 <br /> 1 hereby certify that the plans and specifications covered by Review of the plans and 041 S ?� <br /> this calculation are in compliance with the Florida Energy specifications covered by this 1+ Off, <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. rfr,lr; ,'o;; <br /> PREPARED BY: DayP Before construction is completed <br /> DATE: this building will be inspected for a <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as d s' ned, is in compliance Florida Statutes. 1 �� <br /> with the Florida Energy Code. COD <br /> OWNER/AGENT: JUL 3 1 20 BUILDING OFF'`�I <br /> DATE: DATE: �lJt7 L o L . <br /> - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct.leakage to outdoors, <br /> tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. <br /> 4/1 21201 9 2:46 PM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 4 <br />