My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21715
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21715
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2020 7:52:11 AM
Creation date
5/11/2020 7:52:02 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-21715
Building Department - Name
LENNAR HOMES INC
Address
39636 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Building and Construction Services(BCS) <br /> PA ON C <br /> k?� <br /> COUNTY FLORII A Blower Door Test Report Form <br /> Property Address: Unit#: <br /> j, <br /> Permit#:- g C go n N �s <br /> I's <br /> Test Date: Te er KTre. s <br /> Tester Cert#: ontact Phone <br /> 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 <br /> The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes <br /> per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). As required by <br /> the Building Official, testing shall be conducted by an approved third party. A written report of the results of the test <br /> shall be signed by the party conducting the test(including Agency Name) and provided to the Building Official prior <br /> to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled <br /> penetrations of the building thermal envelope. <br /> During testing:(check to verify condition met) <br /> ❑ Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended <br /> weather-stripping or other <br /> ❑ Dampers including exhaust, intake,makeup air,backdraft and flue dampers shall be closed, but not sealed beyond <br /> intended infiltration <br /> ❑Interior doors,if installed at the time of the test,shall be open <br /> ❑ Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed <br /> ❑ Heating and cooling systems,if installed at the time of the test,shall be turned off <br /> ❑Supply and return registers,if installed at the time of the test,shall be fully open <br /> Vb Building volume(W) = y� ► — <br /> Qso Airflow at 50 Pascal(CFM) = 7 G — <br /> ACHso Air changes per hour at 50 Pascal <br /> Q5o x 60 Vb = 6 F 7 -3 ACH5o (3.o ACH minimum) <br /> Pass ;!�i Fail M <br /> 0 Outside Air mechanically introduced to space(less than 3.0 ACH <br /> I hereby certify that the above envelope leakage performance results demonstrate compliance <br /> with Florid ergy Code requirements in accordance with Section R40,2.4.1.2. <br /> 1 ,3w.. <br /> IA <br /> ature of Tester Date <br />
The URL can be used to link to this page
Your browser does not support the video tag.