My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21715
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21715
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2020 7:52:11 AM
Creation date
5/11/2020 7:52:02 AM
Metadata
Fields
Template:
Building Department
Company Name
HIDDEN RIVER
Building Department - Doc Type
Permit
Permit #
19-21715
Building Department - Name
LENNAR HOMES INC
Address
39636 DAWSON CHASE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jet Stream° Ultra Blowin Wool Insulation NA D <br /> AM'( and cavi'l►Wall Card <br /> Batts and Blankets Equipment Required <br /> When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum W internal corrugation,a minimum length <br /> recommendations,Knauf Insulation baits and blankets will of 150'.Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35lbs/minute.Recommended feed <br /> provide the full R-value. rate is 15-25 lbs/minute. <br /> R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) <br /> To obtain an The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the <br /> fnsnlallon resistance Installed Insulation should required number of bags per 1,000 square fee(and e>sceeding the m9mum square feet of coYerage per bag a5 recommended by the label <br /> (R-Value)of: not be less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. <br /> R-49 13.75" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. <br /> R-38HD 10.25" <br /> R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum <br /> To obtain an The number of bags Coverage per Bag Weight per SF <br /> R 30HD 8.25° insulation per 1,000 square feet Contents of this The weight per square <br /> R-30 10.00" Cavity resistance of net area should not bag should not feet of installed Insulation <br /> R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: <br /> R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. <br /> R-21 HD 5.50" 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs. <br /> R-19 6.25°" <br /> R-15HD 3.50° 2"x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs. <br /> R-13 3.50" 2"x 10" 9.25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. <br /> R-11 3.50" •R means resistance to heat flow.The higher the R-value,the greater the insulating power.To gel the marked R-value,it is essential that this insulation be Installed properly <br /> R-8 2.50" <br /> "R-18 in a 5.5'cavity Conforms to ASTM C 665 and Federal Open Attic Application Bag Net Weight-Nominal 321bs.,Minimum 31 lbs. <br /> Specification HH-1-521F. Minimum <br /> Bags/ Maximum Minimum Initial Settled <br /> Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** <br /> To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/SF ht/SF Thickness <br /> 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* g contents of this <br /> q 1,000 SF of net area hag should not of installed Installed insulation bag should <br /> Ba s/MSF Ba s/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more <br /> 9 9 resistance(R-Value)of: than: more than: be lesslhan than: than: <br /> Joist O.C. Framing O.C. <br /> Framing <br /> R-Value Dimensions Framing Framing R-60 29.7 33.6 SF .952 lbs. 19.750' 19.750" <br /> 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs. 16.375" 16.375" <br /> R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670lbs. 14.875" 14.875" <br /> 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000" <br /> 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375" <br /> R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125" 9.125" <br /> 2x8 2 .4 2 . <br /> 2x4 20.4 20.6 R-22 9.8 102.2 SF .313 lbs. 7.750" 7.750" <br /> R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750" 6.750" <br /> 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750" <br /> 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000" 4.000" <br /> R-38 2x6 17,0 17.2 Bag Net Weight-Nominal32 Ns.,Minimum 31 lbs. <br /> 2x8 16.7 17.0 Coverage and instagadoo data were determined using a Volu-Malic"II Mowing machine In third gear with I gate opening,2.0 psi air pressure and 150'of 3'Inlematiy-corrugated hose. <br /> 2x4 13.2 13.3 This product conforms to the performance requirements of ASTM C 764,Type 1,and cancelled Federal Spedfulkit HH-1.1030B,Type I,Class B.R-values are determined in accordance with C 687 and C 51a. <br /> "R•means resistance to heat flow.The higher the R-value,the greater the insulating power.To get the marked R-va4e,c is essential that this insulation be Installed properly.it you do B yourself,get inslmo- <br /> R30 2x6 12.9 13.1 tions and follow them carefully.Instructions do not come with this package. <br /> -Based an Third Party 2-year settling study,the predicted settlement wer a 20-year period would be 1 percent or less.This amount of settling is thermally Insignificant Therefore,the Installed and settled <br /> 2x8 12.6 12.9 thicknesses are effec"the same. <br /> 2x4 11.3 11.4 Vdu-Mat011 is a registered trademark of Unisul. <br /> R-26 2x6 11.0 11.2 Builder's Insulation Statement <br /> 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... <br /> 2x4 9.3 9.5 R-Value Thickness <br /> R-22 20 9.1 9.3 Attic Area R- Sc�, at a Inches <br /> 2x8 818 9.1 Sloped Ceilings R- at Inches <br /> 2x4 7.9 8.1 Walls R- at Inches <br /> R-19 2x6 7.7 7.9 Floors(over an unheated crawl space) R- at Inches <br /> 2x8 7.4 7.7 <br /> 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches <br /> R-13 2x6 5.0 5.2 Date Installed /Z•gam•!I <br /> 2x8 4.8 5.0 Blown insulation has been installed in conformance with the above recommendations to provide an R-value of: <br /> 2x4 4.3 4.4 R d3 using J I- bags of this insulation to cover square feet of area <br /> R-11 2x6 4.1 4.3 at a minimum thl knes f in <br /> 2x8 3.8 4.1 <br /> r�` r <br />
The URL can be used to link to this page
Your browser does not support the video tag.