My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21856
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21856
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/11/2020 9:26:05 AM
Creation date
5/11/2020 9:25:59 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21856
Building Department - Name
DR HORTON INC
Address
7101 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ID <br /> V <br /> 0 <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E.. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3:. Compaction test required.if 24" or more of fill_dirt is brought in at any one place. <br /> 4. Tie'in survey required before pouring concrete. <br /> 5: Driveways require.a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7-. All property markers shall be uncovered-and marked at time of first inspection. <br /> & All A.D.A.requirements shall be met. <br /> 9-. No electric,-plumbing;techanical, or framing shall.be covered without an inspection and <br /> approval-first. <br /> 10. All Garages shall comply with section R302'.6 of the F.B.-C. (Fire Separation). <br /> 1.1. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M301-4 of the P.B.C. <br /> 12. Water heaters shall comply with section P607.3 of the E.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308..1 <br /> 14; Returh air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the F.B:C; <br /> 17. All means.of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum,board" shall not be used as a backer in showers or tubs.R702.4.2 F.B.C. <br /> 10; Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 21 All 2om N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.