Envelope Leakage Test Report (Blower Door Test) <br /> Residential Prescriptive, Performance or ERI Method Compliance <br /> 2017 Florida Building Code, Energy Conservation, 6th Edition <br /> Jurisdiction: 1 ' q, vle.hl, Permit#: <br /> Job Information: <br /> Builder:[�J ear G( f Community:` 4j- r� Lot <br /> Address: <br /> City: ' ` - l State: Florida - Zip <br /> Air Leakage Test'ReSURS: Passing results must meet elither the Performance,Prescriptive,or o'ER1Methd••,, �- <br /> ® PRESCRIPTIVE'METHOD-The building~ordwelling unit shall_be tested and Kgrifie_d as having an air leakage rate'ofnot exceeding 74air changes <br /> per hour at a-pressure of 0.2-inch w.g':.(50 pascals)in.Climate Zones 1 and 2. <br /> ❑PERFORMANCE or EOI METHOD-The.building or dwelling unit shall be tested and verified as having an'airleakage rate of not exceeding the <br /> selected A'CH(50)value,a"sshowrf on FORM R405-20J 7(Performance)or R406-2017(ERI),section labeled as Infiltration,`s 47section ACH <br /> > /OACH(50)specified on Form R405-2017-Ener Calc(Performance)or R406-2017(ERI): <br /> Method for calculatins building volume`s <br /> 1 ' 7 `/ X 60 / /.2 = c�-� ® Retrieved from architectural plans <br /> CFMso- Building Volume ACHso r 1 ` <br /> � 1 1 1 ❑ Code software calculated ,. <br /> f - PASS 07 'FAIL <br /> El When ACH50 is lessthan 3=ACHso,,Mechanical VentilationdField measured;and calculated 0 Field measur' d and calculated �I <br /> in <br /> be verified by building department. <br /> Testing.Testingshallbe conducted in accordance with AN51/RESNET/ICC380andreportddata pressure or0.2inchesw.g:(50Pascals) Testingshallbeconductedbyeither i <br /> individualsasdefinedinSection553.993(5)or(7),Floridastatues,orindividualslicensedassetforthinsection <br /> y 489.105(3)(1),(g),or(i)oran approved third party.Awrittenreport-of the results ofthe',iest shall be slgned.bythe party cond ucting the test and-proviclecl tothe code officiaL <br /> Testing shall be performed atanytimeaftercrdationofaIIpenetrationsoftlid_bu'ildingtiiermalenvelopeJ' <br /> D,uting testing: <br /> II L`Exterior windows and doors,fireplaceand stove doors shall be closed,but not sealed,beyond the intended weather-strippingor other infiltration control measures. I <br /> �2.=' s including exhaust,intake,makeup air,backdraftand flue dampers shall be closed,but notsealed beyond intended infiltrationcontrol measures. <br /> 3.Interior doors,if installed at the time of the test,shall be open. <br /> 4!Exte`rior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. <br /> 5.9Heating and cooling systems,if installed at the time of the test,shall be turned off. i <br /> 6.suppl ,`.and return registers,if installed at the time of the test,shall be fully open. i <br /> a ', :,♦ ff: .'� sr <br /> Testing Company t <br /> Company Name: airEnalasys%-:, Phone: 877-437-7728 <br /> I hereby verify that the above Air Leakage resu'Its'arejnaccordancewith the 2017 6th Edition Florida Building Code EnergpJ, , <br /> Conservation requirements according to the compliance=method selected^above:.=�! <br /> Signature of Test <br /> Quo. - Date of Test: <br /> Printed Name of Tester: ~'`�,11Villi6m_Mago >, 4 l <br /> Lice nse/Ce rtificatio n# RESNET 43,09320-:� - --- - __..Jssuing Authority: __—FSEC <br />