Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21947
Building Department - Name
DR HORTON INC
Address
7142 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Wrightsoft® <br /> Manual S Compliance Report Da <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: Hayden 2605 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton <br /> Lot 26 Blk 7 Silverado, Zephyrhills, FL <br /> Cooling • • <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 31195 Btuh Entering coil DB: 76.4°F <br /> Outdoor design WB: 77.1 OF Latent gain: 4122 Btuh Entering coil WB: 63.2°F <br /> Indoor design DB: 75.0°F Total gain: 35317 Btuh <br /> Indoor RH: 50% Estimated airflow: 1367 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Sensible capacity: 32444 Btuh 1040%of load <br /> Latent capacity: 6297 Btuh 153%of load <br /> Total capacity: 38741 Btuh 110%of load SHR: 84% <br /> Heating Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 27188 Btuh Entering coil DB: 69.5°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB042+FB4CNP042 <br /> Actual airflow: 1367 cfm <br /> Output capacity: 37285 Btuh 1370%of load Capacity balance: 31 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1367 cfm <br /> Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF <br /> Meets are all requirements of ACCA Manual S. <br /> I'1 IltSOft, 2019-Aug-26 09:40:05 <br /> W <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ACCK ..press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: W <br />