My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-21947
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-21947
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 9:47:11 AM
Creation date
2/17/2021 9:47:09 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-21947
Building Department - Name
DR HORTON INC
Address
7142 SILVERADO RANCH BLVD
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
® Load Short F Job: <br /> -�- Wrightsoft ortorm Date: <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: Hayden 2605 <br /> 5907 Dasher Ct,Port Richey,FL 3466E Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> Project • • <br /> For: DR Horton <br /> Lot 26 Blk 7 Silverado, Zephyrhills, FL <br /> Design Information <br /> Htg Clg Infiltration <br /> Outside db(OF) 40 91 Method Simplified <br /> Inside db (OF) 70 75 Construction quality Semi-tight <br /> Design TD (OF) 30 16 Fireplaces 0 <br /> Daily range - L <br /> Inside humidity (%) 50 50 <br /> Moisture difference(gr/lb) 26 54 <br /> HEATING EQUIPMENT COOLING EQUIPMENT <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NBO42 Cond CH14NBO42 <br /> AHRI ref Coil FB4CNP042 <br /> AHRI ref <br /> Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER <br /> Heating input Sensible cooling 30750 Btuh <br /> Heating output 38500 Btuh @ 470F Latent cooling 10250 Btuh <br /> Temperature rise 26 OF Total cooling 41000 Btuh <br /> Actual air flow 1367 cfm Actual air flow 1367 cfm <br /> Air flow factor 0.050 cfm/Btuh Air flow factor 0.044 cfm/Btuh <br /> Static pressure 0.56 in H2O Static pressure 0.56 in H2O <br /> Space thermostat Load sensible heat ratio 0.88 <br /> Capacity balance point=31 OF <br /> Backup: <br /> Input=9 kW, Output=29290 Btuh, 100 AFUE <br /> ROOM NAME Area Htg load Clg load Htg AVF Clg AVF <br /> (ft.) (Btuh) (Btuh) (cfm) (cfm) <br /> living 277 2486 3486 125 153 <br /> bed 2 164 2826 1882 142 82 <br /> bath 2 59 965 367 49 16 <br /> flex 163 2901 3098 146 136 <br /> foyer 69 1332 881 67 39 <br /> stairs 40 0 0 0 0 <br /> bed 4 175 1843 2055 93 90 <br /> bed 3 183 2067 3217 104 141 <br /> wic 57 144 181 7 8 <br /> wic 2 30 767 855 39 37 <br /> m suite 287 2737 3956 138 173 <br /> m bath 103 330 294 17 13 <br /> upstairs living 226 1220 2484 61 109 <br /> stairs 2 50 0 0 0 0 <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> -rh- wri htsoft® 2019-Aug-26 09:40:05 <br /> 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 <br /> ACCX ..press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.