My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22144
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22144
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/17/2021 10:18:24 AM
Creation date
2/17/2021 10:18:23 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-22144
Building Department - Name
DR HORTON
Address
7102 BOXER ROUND PL
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
•�I <br /> D <br /> Q <br /> V <br /> lob <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. <br /> I Lots shall be graded to comply with R401.3 of the F.B.C. <br /> 3: Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R,O.W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7. All property markers shall be uncovered and marked at time of first inspection. <br /> & All A.D.A."requirements shall be met. <br /> 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and <br /> approval first. <br /> 10. All Garages shall comply with section R3016 of the F.B.-C. (Fire Separation). <br /> 11,. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by approved barriers. M303..4 of the RB.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M 1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313:1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308.4 of the RB:C; <br /> 17. A11 means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green gypsum Board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker-. <br /> 20. Carbon monoxide alarms will be required in ne.W construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed in accordance with the F.B.C. <br /> 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all <br /> Under-ground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />
The URL can be used to link to this page
Your browser does not support the video tag.