My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22170
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22170
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 10:52:58 AM
Creation date
2/17/2021 10:44:10 AM
Metadata
Fields
Template:
Building Department
Company Name
SILVERADO
Building Department - Doc Type
Permit
Permit #
19-22170
Building Department - Name
GONZALEZ,AUSTIN SCOTT & SCARLET
Address
6694 WAGON TRAIL ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J <br /> a <br /> Snow Load 21-30 psf <br /> Modules in Landscape <br /> Wind Speed Exposure 2:12<Roof Pitch<.6:12 7:12<Roof Pitch-C I v <br /> ASCE 7-06 ASCE 7-10 Category Zone 1 Zone 2 Zone.3 Zone 1 Zone*2 . Zone 3 . <br /> B 93 59 <br /> 85 mph 110 mph C •67 42 <br /> D 96 . 56 35 <br /> B 85 54 <br /> 90•mph 115.mph C 104 61 38 <br /> D- 88 51. 32 <br /> B. 72 45' <br /> 100.mph 125'mph . C 88 51 32 <br /> D 74 - 43 27 57 57 <br /> B 98 57 36 <br /> 110 mph 140 mph C 70 41 26 66 54 54 <br /> D 59 34 22 56 46 46 <br /> B . 85 50 31 66 66 <br /> 120 mph 150 mph, C 61 - 36 22 58 47 47 <br /> D 51 30 19 49 40 40 <br /> Notes: <br /> Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet appropriate rafter spacing <br /> 2.)Maximum allowed spacing approved by EcoFastan Solar Is-72" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)includes additional factor of safety of.1.5 for lag pullout capacity <br /> 5.)Values based on a maximum-module width of 40" <br /> 6:)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1.No site specific engineering is Included In this table <br /> Snow Load.21-30 psf. <br /> Wind.Speed Exposure 2:12<Roof Pitch<6:12 7:12'<Roof Pitch<12:12 <br /> ASCE 7-05' ASCE 7-10 Category Zonal Zone 2 Zone 3 Zone 1 Zone 2. Zone 3 <br /> B 53,E-1 .�''33v-22 <br /> 85 mph 110 mph C ti5 38 24, <br /> l� <br /> �_ <br /> B 49 30 <br /> 90 mph 115 mph C 59 35 22 <br /> D 50 29 18 38 38 <br /> 100 mph , 125 mph J' C 50 29 18 <br /> D _ 42 _26, 15- <br /> B 56 33 20 <br /> 110 mph 140 mph C 40 23 14 38 31 31 <br /> D 34' 19 12 32 26 26 <br /> - - — 49 �28 18 Y '`- 3737 .' <br /> 120 mph 150 mph C 35 20 12 { 33' 27 r "'2 0. <br /> D 29 17 10 , 28 22 <br /> Notes: <br /> -Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in Inches forrpuiloui forces only.on EcoFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)includes additional factor of safety of-1.5 for lag pullout capacity <br /> 5.):Values based-on a.maximum module length of 70" <br /> 6.)Based on Risk Category If(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to i1..No.site specific engineering Is included in this table <br /> -www.ecofastensolarcom info@ecofastensolarcom 877-859-3947 9 <br />
The URL can be used to link to this page
Your browser does not support the video tag.