Laserfiche WebLink
Snow Load 0-20 psf <br /> Modules in Landscape <br /> Wind Speed Exposure 2:12<Roof.Pltch•e 6:12 1. .7:12 a Roof Pitch a 12:12. <br /> ASCE 7-05 ASCE 7-10 Category, Zone 1 Zone 2 Zone 3 Zone 1 Zone 2 Zone 3 <br /> B 159 93' 59 <br /> 85 mph 110 mph C 114 67 42 88 88 <br /> D. 96 _ 56 35 91 74 '74 <br /> B 146 85 54 <br /> 90 mph 115 mph C 104 61 38 98 80 80 <br /> D 88 51 32- 83 68 68 <br /> B 123 •72 45 95 ' 95 <br /> 100 mph 125 mph' C 88 51 32 83 68 68 <br /> D 74 " 43 27. 70" 57 .57 <br /> B 98 57 36 93 76 �76 <br /> 110.mph . 140 mph. C 70 41 26 66 54 54 <br /> D 59 34 22. 55 46. 46 <br /> B .85 50 31 81. 66 66 <br /> 120 mph 150 mph. - .. C 61 36 22. .58 47 47 <br /> D 51 30 19 49 40 40 <br /> .Notes: <br /> Spacing Governed by Snow Load <br /> 1.)Values in above table represent the.maximum allowable spacing in Inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet appropriate rafter.spacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 72" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.5 for lag.pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6.)Based on Risk Category 11(ASCE 7-10)'structures less than 30 feet in height <br /> 7.)All adjustment-factors are set to 1.No site specific engineering Is included in this table <br /> Snow toad'0 20 psf <br /> Wind Speed Exposure 2:12.<Roof Pitch.<6:12 1 712<Roof Pitch x'12:12 <br /> ASCE 7-05 ASCE 7=10 CAtegog Zonal Zone 2 Zone-3 Zone.1 Zone 2 one 3 <br /> -- _ -- - - B 91 - - -53.r.__--__33 <br /> 85 mph 110 mph , C 65 38 24 61-. 60 -z50,irk:.` <br /> D 55 _ 32 2Q <br /> B 83 _ -49 30 <br /> 90•mph 115 mph C 59 35 22 56 46 46 <br /> D 50 29 18. 47 38 -38 <br /> 70_ 41—v <br /> 100 mph 125 mph C 50 29 18 47 "' ' 39 39p <br /> D 42 26 1 1.5.. , . .40 32 321 <br /> B 56 7 33 20 53 43 43 <br /> 110 mph 140 mph. C 40 23 14 38 31 31 <br /> D 34 19 12 32 26 26 <br /> - — - B __ 49 _ —- 28 <br /> 120 mph 150 mph C 35 20 12 33 27 27 <br /> D 29 17 10 28 22 22 <br /> Notes: <br /> _Spacing Governed by.Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff <br /> 2:)Maximum allowed spacing approved by EcoFasten Solar Is 48" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety of 1.6 for-lag pullout capacity <br /> 5.)Values based on a maximum module length.of 70" <br /> 6:)Based on Risk Category Il(ASCE 7-10)structures less than 30 feet in height. <br /> 7.)All adjustment-factors are set to 1..No site specific engineering is included in this table <br /> www.ecofastensolarxom info@ecofastensolarcom 877=859-3947 '8: <br />