Laserfiche WebLink
INSULATION COVER BOARD <br /> Georgia-Pacific <br /> DensDeckTechnical Service Hotline 1.80OM5,8119 or <br /> Roof Board www.densdeck.com <br /> Manufacturer Confirm any priming requirements with the membrane manufacturer.When applying <br /> Georgia-Pacific Gypsum Georgia-Pacific Canada solvent-based adhesives or primers,allow sufficient time for the solvent to Flash off <br /> 133 Peachtree Street 2180 Meadowvale Boulevard,Suite 200 to avoid damage to roofing components. <br /> Atlanta,GA 30303 Mississauga,ON L5N 5S3 DensDeck Roof Boards should not be subjected to abnormal or excessive loads or <br /> Technical Service Hotline:1-B00-225.6119 foot traffic,such as,but not limited to,use on plaza decks or under steel-wheeled <br /> Description equipment that may fracture or damage the panels.Provide suitable roofing system <br /> DensDockm Roof Board is an exceptional fire barrier,thermal barrier,coverboard protection when required. <br /> and recovery board used in various commercial roofing systems.The DensDeck When using DensDeck Roof Boards for hot-mapped applications,Georgia-Pacific <br /> Roof Board design employs fiberglass mats front and back that are mechanically recommends maximum asphalt application temperatures of 425°F(218°C)to 450°F <br /> bonded to a high density gypsum care,providing excellent fire resistance and (2321C),Application temperatures above these recommended temperatures may <br /> wind uplift properties.The unique construction of DensDeck Roof Board provides adversely affect roof system performance.Consult and follow the roofing system <br /> superior flute spanning that stiffens and provides increased foot traffic resistance manufacturers specifications for full mopping applications and temperature <br /> to the roof deck.Additionally,DensDeck Roof Board has been shown to withstand requirements. <br /> delamination,deterioration and job-site damage far more effectively than roofing Conditions beyond the control of Georgia-Pacific,such as weather conditions,dew, <br /> membrane substrates such as paperfaced gypsum board,fiberboard and perlite leaks,application temperatures and techniques may cause adverse effects with <br /> insulation.DensDeck Roof Board has scored a 10,the highest level of performance roofing systems. <br /> for mold resistance per the AS€M D3273 test method. <br /> Moisture Management <br /> Primary Uses <br /> DensDeck Roof Boards,like other components used in roofing systems,must <br /> Roof system manufacturers and designers have found DensDeck Roof Board to be <br /> be protected from exposure to moisture before,during and after installation. <br /> compatible with many types of roofing systems,including:built-up,modified bitumen, <br /> single ply,metal systems,wood shingly and shake,tile,slate,as well as a recovery Remove the plastic packaging from all DensDeck Roof Board immediately upon receipt <br /> board and ovedayment protection board for polyisocyanurate and polystyrene insulation, of delivery.roisturr remove the plastic packaging may result in entrapment of can- <br /> board <br /> DensDeck Roof Board can also be used as a form board for poured gypsum concrete densation or moisture.DensDeck Roof Board stored outside must be stared level and <br /> deck in roof applications as well as a substrate for spray foam roofing systems.1/2" off the ground and protected by a breathable waterproof covering.Provide means for air <br /> (12.7 mm)and 5/8"(15.9 mm)DensDeck Roof Board may also be used in vertical circulation around and under stored bundles of DensDeck Roof Board,DensDeck Roof <br /> applications as a backer board or liner for the roof side of parapet walls. Board must be covered the same day as installed, <br /> Some membrane manufacturers have hot mop asphalt or torch applications directly Avoid application of DensDeck Roof Boards during rain,heavy fog and any other <br /> to DensDeck Roof Board without using a primer or base sheet.Consult with the conditions that may deposit moisture on the surface,and avoid the overuse of <br /> system manufacturer for their recommendations with this application.DensDeck non-vented,direct-fired heaters during winter months.When roofing systems are <br /> Roof Board is the preferred substrate for vapor retarders. installed on new poured concrete or light weight concrete decks or when re-roofing <br /> over an existing concrete deck,a vapor barrier should be installed above the concrete <br /> Standards and Code Approvals to limit the migration of water from the concrete into the roof assembly.Always <br /> DensDeck Roof Boards are manufactured to meet ASTM C1177 and have the consult the roofing system manufacturer or design authority for specific instructions <br /> following approvals: for applying other products to DensDeck Roof Boards. <br /> •Florida Product Approved Moisture vapor movement by convection must be eliminated,and the flow of water <br /> •Miami-Dade County,Product Control Approved by gravity through imperfections in the roof system must be controlled.After a leak <br /> Recommendations and Limitations has occurred,no condensation on the upper surface of the system should be tolerated, <br /> DensDeck Roof Boards are manufactured to act with a properly designed roof system and the water introduced by the leak must be dissipated to the building interior in a <br /> following good roofing practices.The actual use of DensDeck Roof Board as a roofing minimum amount of time. <br /> component in any system or assembly is the responsibility of the roofing system's Although DensDeck Roof Boards are engineered with fiberglass facings and high density <br /> design authority.Consult with the appropriate system manufacturer and/or design gypsum cores,the presence of free moisture can have a detrimental effect on the <br /> authority for system and assembly specifications and instructions on applying other performance of the product and the installation of roofing membranes.For example, <br /> products to DensDeck Roof Board.Georgia-Pacific does not warrant and is not hot asphalt applications can blister;torched modified bitumen may not properly bond; <br /> responsible for any systems or assemblies utilizing DensDeck Roof Board or any and adhesives for single ply membranes may not dry properly.Moisture accumulation <br /> component in such systems or assemblies other than DensDeck Roof Board. may also significantly decrease wind uplift and vertical pull resistance in the system or <br /> The need for a separator sheet between the DensDeck Roof Board and the roofing assembly.DensDeck Roof Boards containing excessive free moisture content may <br /> membrane must be determined by the root membrane manufacturer or roofing need to be evaluated for structural stability to assure wind uplift performance. <br /> system designer. <br /> Submittal Job Name conrinue&- --- <br /> Approvals <br /> Contractor <br /> Date <br /> APPLIED IN ADHESIVE <br /> 4 FT X 4 FT MAX BOARD SIZE <br /> 1/4"THICKNESS Stamps f Signatures <br />