My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
19-22093
Zephyrhills
>
Building Department
>
Permits
>
2019
>
19-22093
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/18/2021 11:09:24 AM
Creation date
2/17/2021 11:57:37 AM
Metadata
Fields
Template:
Building Department
Company Name
NESTLE WATERS NORTH AMERICA
Building Department - Doc Type
Permit
Permit #
19-22093
Building Department - Name
NESTLE WATERS NORTH AMERICA
Address
4330 20TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
82
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Georgia-Pacific <br /> Dens®eck" Technical Service Hotline 1.800.M.6119 or <br /> Roof Board www.densdeck.clom <br /> Fire Resistance Classifications UL Fire Resistance Ratings 5/8"(15,9 mm)DensDeck Fireguard Roof Boards are <br /> DensDeck°Roof Boards are excellent fire barriers over combustible and noncombustible designated as Type DO by UL and included in assembly designs investigated by UL <br /> roof decks,including steel decks. for hourly fire resistance ratings.5/8"(15.9 mm)DensDeck Fireguard Roof Boards may <br /> UL 790 Classification, DensDeck Hoof Boards have been classified by Underwriters also replace any unclassified 5/8"(15.9 min)gypsum board in an assembly in the UL <br /> Laboratories(UL)for use as a fire barrier over combustible and noncombustible decks Fire Resistance Directory under the prefix"P". <br /> in accordance with the ANSI/UL 790 test standard.The UL classification includes a Flame Spread and Smoke Developed. When tested in accordance with ASTM E84, <br /> comprehensive Class A,8 or C rating.For additional information concerning the UL 790 DensDeck Roof Boards had Flame Spread 0,Smoke Developed 0. <br /> classification,consult the UL Certification Directory. Wind Uplift <br /> UL 1156 Classification, DensDeck Roof Boards have also been classified by UL in roof DensDeck Roof Boards are included in numerous assemblies evaluated by FM or other <br /> deck constructions for internal(under deck)fire exposure in accordance with the independent laboratories for wind uplift performance.For information concerning such <br /> ANSI/UL 1256 Steiner Tunnel test.For additional information concerning the UL 1256 assemblies,please visit www.roofnay.com. <br /> classification,consult the UL Certification Directory. Handling and Use-CAUTION <br /> FM Class 1 Approvals. DensDeck Roof Boards are included in numerous roofing This product contains fiberglass facings which may cause skin irritation.Dust and <br /> assemblies with a Factory Mutual(FM)Class 1 fire rating.1/4"(6.4 mm)DensDeck fibers produced during the handling and installation of the product may cause skin, <br /> Roof Boards have passed testing under the FM Calorimeter Standard 4450 and have eye and respiratory tract irritation.Avoid breathing dust and minimize contact with <br /> been approved by FM as such for insulated steel deck roofs when installed according skin and eyes.Wear long sleeve shirts,long pants and eye protection.Always <br /> to the conditions identified by FM.For more information concerning FM Approvals and maintain adequate ventilation.Use a dust mask or NIOSH/MSHA approved <br /> FM Class 1 assemblies with DensDeck Roof Boards,consult FM or RoofNav", respirator as appropriate in dusty or poorly ventilated areas. <br /> Type X 5/8"115.9 mm)DensDeck°Fireguard"Roof Boards are manufactured to meet <br /> the"Type X"requirements of ASTM C1177 for increased fire resistance beyond <br /> regular gypsum board. <br /> Physical Properties 1/4" THICKNESS <br /> Properties <br /> Thickness,nominal 1/4"(6.4 mm)±1/16"(1.6 mm) 1/2"1123 min)±1/32"I.B min) 5J8"(15.9 mml±1/32"(.8 min) <br /> Width,standard 4'(1219 min)±1/8"(3 min) 4'(1219 mm)±1/8"1 mml 4'(1219 mm)31/8"13 mm) <br /> Length,standard B'(2438 min)±1/4"(6.4 min) 8'(2438 mm)±1/4"(6.4 mm) 1 8'(2438 mml±1/4"(6.4 min) <br /> Weight,nominal,lbs./s .ft.(Kg/mt) 1.2(5.9) 2.0(9.01 1 25112.2) <br /> Surfacing Fiberglass mat Fiberglass mat Fiberglass mat <br /> Flexural Strength',parallel,lbf.min.(N) 24D(178) a80(356) 2:100(444) <br /> Flute Spanabilityr _ 2-5/8"(67 min) 5"(127 mm) B"(203 min <br /> Permeance',Perms(ng/Pa•S-ml) >50(2B50) >35(19951 >32(1B24) <br /> R Value',ft--'F•hr/BTU(mt•K/W) .28 .56 .67 <br /> Linear Variation with Change in Temp., <br /> in/in°F(mm/mm/C°) 8.5 x 101(15.3 x 101) 8.5 x 101(15.3 x 10-5) 8.5 x 106(15.3 x 1061 <br /> Linear Variation with Change in n Moisture _ 6.25 x 106 6.25 x 10 6 6.25 x 196 <br /> Water Absorption,%max <10 <10 <10 <br /> Compressive Strength',psi nominal { 90D 900 90D <br /> Surface Water Absorption,grams,nominal <2.5 <2.5 <2.5 <br /> Flame Spread,Smoke Developed(ASTM E841 0/0 0/0 0/0 <br /> Bending Radius 5'(1524 min) 812438 mm) 12'(3658 min) <br /> 1.Tested in accordance with ASTM C473 method 6. 4.Tested in accordance with ASTM C518 Cheat flow meter/. <br /> 7.Tested in accordance with ASTM E661. 5.Tested in accordance with ASTM C1177. <br /> 3.Tested in accordance with ASTM E96(dry cup method). 6.Tested in accordance with ASTM C473. <br /> TRADEMARKS DENSDECK,FIREGUARD and the GEORGIA-PACIFIC logo are trademarks owned by <br /> Ge®rgla"PI'a cif lc or licensed to Georgia-Pacific Gypsum LLC.ROOFNAV is a registered mark of FM Global. <br /> Gypsum WARRANTIES,REMEDIES AND TERMS OF SALE For current warranty information for this <br /> product,please go to www.gpgypsum.com and select the product for warranty information.All sales <br /> of this product by Georgia-Pacific are subject to our Terms of Sale available at www.gpgypsum.com. <br /> USA. Georgia-Pacific Gypsum LLC y a without UPDATES AND CURRENT INFORMATION The information in this document may change <br /> Georgia-Pacific Gypsum II LLC 9 <br /> Canada Georgia-Pacific Canada LP notice.Visit our website at www.gpgypsum.com for updates and current information. <br /> SALES INFORMATION AND ORDER PLACEMENT CAUTION For product fire,safety and use information,go to www.buildgp.com/safetyinto <br /> U.SA. West: 1-80 M44503 or call 1-600-225-6119. <br /> Midwest: 1-MM764746 FIRE SAFETY CAUTION Passing a fire test in a controlled laboratory setting and/or certifying or <br /> South Central: 1-800.231-6060 labeling a product as having a one-hour,two-hour,or any other fire resistance or protection rating <br /> Southeast: 1-ti00-327-2344 and,therefore,as acceptable for use in certain fire rated assemblies/systems,does not mean that <br /> Northeast: 1-800-947-4497 either a particular assembly/system incorporating the product,or any given piece of the product <br /> CANADA Canada Toll Free:1-BOD-387-SM itself,will necessarily provide one-hour fire resistance,two-hour fire resistance,or any other <br /> Quebec Toll Free:1-680.361-o4B6 specified fire resistance or protection in an actual fire.In the event of an actual fire,you should <br /> TECHNICAL INFORMATION immediately take any and all actions necessary for your safety and the safety of others without <br /> USA and Canada:/-M-2254119,www gpgypsum com regard for any fire rating of any product or assembly/system. <br /> 010I5 Geor0afx fc Gypsum LLC.A,l rghu roemed 5115 GMM Lit Item I101516 <br />
The URL can be used to link to this page
Your browser does not support the video tag.