Laserfiche WebLink
FORMS <br /> TABLE R402A <br /> BUILDING COMPONENT PRESCRIPTIVE REQUIREMENTS! INSTALLED VALUES <br /> Climate Zone I Climate Zone 2 <br /> Windows U-Factor-NR LWactor=0.402 U-FacOr <br /> SHGO=0.25 SHGC=0.25 SHOO--b: <br /> Skylights_ U-factor=0.75 U-factor=0.65 U-factce= <br /> IISHGC=0.30 SHGC=0.30 SHdO& <br /> Doors:Exterior doorr U-factor=NR (J-factor=OACP I'Lfaclor <br /> Roors: <br /> Slab-on-Grade Nk NR <br /> Over unconditioned spaces' R-13 8-13 Pi-value <br /> Walls':Ext,and Adl. <br /> Frame R-13 R-13 R-Value <br /> Mass <br /> Insulation ortwall interior R-4 R-6 R-Value <br /> Insulation on wall exterior R-3 0-4 R-Value <br /> Ceilings` R=30 8=38 R-ValLe <br /> Air infiltration Blower door test is requited on the building envelope to verify leakage<I ACH; Total leakage=ACH <br /> test report provided to code official. Test report aftached? <br /> Yes 0 No[3 <br /> Air distribution systems: <br /> Air handling unit Not allowed in aide <br /> Due,t R-vatue R-value—>R-8(supply in attics)or>R-6(all other duct locations) (,ocaticn: <br /> R-Vatic <br /> Air leakage: <br /> Duct test Postconstruction test Total leakage:9 4 ofm/1 00 s,f. <br /> Rough-in test Total leakage:5 4 ofm/100 s.f.(air handier inslailed) Total leakage cirm/100s.f. <br /> Total leakage 5 3 cfm/100 sJ.(air handier not,installed) Test report Attached? Yes 13 No E3 <br /> Ducts in conditioned space Test not required,if all ducts and AHU are in conditioned space Locatlix: <br /> Air conditioning system: Minimum federal standard required by NAECAI: <br /> Cori'trat system:9 66,000 Sturn SEER 14.0 <br /> Room unit or PTAC EER(from Table C403.2.3(3)) SEER= <br /> Other: See Tables 0403.2.3(l)-(l 1) EER <br /> Heating system: Minimum federal standard required by NAECA". <br /> Heat pump 5 65,000 Stu/h_ HSPF 8.2 HSPF= <br /> Gas furnace,non-weatherized AFUE 801,16 AFUE= <br /> Oil furnace,non-Weatherized AFUE 83% AFUE= <br /> Other. <br /> Water heating system(storage type): Minimum federal standard required by NAECAI: <br /> EleCtrlC7 40 gal:EF=0.92 Gallons� <br /> 50 gal:EF=0.90 EF= <br /> Gas fired' 40 gal:EF=0.59 Gallons= <br /> , 50 gal:EF=0.58 EF <br /> Other(desc roe): <br /> L <br /> NR=No requirement. <br /> (1)Each component present in the As Proposed home must meet or exceed each of the applicable performance criteria in orderto comply with this code using <br /> this method. <br /> (2)For impact rated fenestration complying with Section R301.2.1-1 of the Florida Building Code.Residential or Section 1609.12 of the Florida Building Code, <br /> Building, the maximum U-factor shall be 0.65 in Climate Zone 2. An area-weighted average of 1-Z:actor and SHGC hall be accepted to meet the <br /> requirements,or up to 15 square feet of-lazed fenestration area are exempted from the (,'-factor and SHGC requiienian.based on Sections R402.3.1, <br /> R402.3.2 and R402.3.3. <br /> (3)One side-hinged opaque door assembly up to 24 square,feet is exempted from this U-factor requirement. <br /> (A)R-values are foe insulation material only as applied in Pccofdance with rnanufacturer s installation instructions. For mass walls, the "interior of wall" <br /> requirement must be met except if at least 50 percent of the insulation required for the''exterior of wall"is installed exterior of.or integral to.the wall. <br /> (5)Ducts&AHU installed-substantially lea,free"per Section R403.3-2.Test required by either individuals as defined in Section 553,993(5)or(7),Florida <br /> Stanues,or individuals licensed as set forth it., Secdon 489.105(3)(t),(g)or(i), Florida Smuites.The total leakage test is not required for ducts and air <br /> handlers located entirely within the building thermal envelope. <br /> (6)Minimum efficiencies are those set by the National Appliance tnerp-Conservation Act of 1987 for typical residential equipment and are subject to NAECA. <br /> rules and regulations. For other types of equipment. see Tables t403.2.3,1 1-11) of the Commercial Provisions of the Fiofida Building Code. Energy <br /> consen.-ation. <br /> .7)For other electric storage volumes,minimum EF=0.97-(0.00132*volume). <br /> (8)For other natural gas storage volumes,minimum EF=0.67-(0,0019*volume), <br /> R-66. FLORIDA BUILDING CODE--ENERGY CONSERVATION,,6,th EDITION(2017) <br />