Laserfiche WebLink
FORMS <br /> TABLE R4029 MANDATORY REQUIREMENTS $ <br /> Component Section Summary of Requirement(s) Check <br /> Air leakage R402.4 To be caulked,gasketed,weatherstripped or otherviise sealed per Table R402.4.1.1.Recassed lighting:(Grated as <br /> having 5 2.0 cfm tested to AST E 283. <br /> Windows and doors:0.3 cfnVsq.ft.(swinging doors:0.5 cfmlerr)when tested to NFRC 40)or <br /> AAMAIWDMA/CSA 101fl.S.2/A440. <br /> Fireplaces:Tight-fitting flue dampers_&outdoor combustion air. <br /> Programmable R403.1.2 A programmable thermostat is required for the primary heating or cooling system. <br /> thermostat Q <br /> R403.3.2 Ducts shall be tested as per Section R403.3.2 by either individuals as defined in Section 553.993(5)or('7),Florida <br /> Air distribution system R403 3 4 Statutes,or individuals licensed as set forth in Section 489A05(3)(0,(g)or 0).Florida Satutes.Air handling units <br /> are not allowed in attics. <br /> Water heaters R403.5 Comply with efficiencies in Table C404.2.Hot water pipes insulated to>_R-3 to kitchen atiets,orher cases. <br /> Circulating systems to have an automatic or accessible manual OFF switch.Heat trap required for ver5cal pipe <br /> risers. <br /> Swimming pools&spas R403.10 Spas and heated pools must have vapor-retardant covers or a liquid cover or other mears proven to reduce heat <br /> loss except if 70%of heat from site-recovered energy.Offltimee switch required.des heaters minimum thermal <br /> efficiency is 82%.Heei pump pool healers minimum COP is 4.0. g <br /> Cooling/heating R403.7 Sizing calculation performed&ar2ched.Special occasion cooling or heating capacity requires separate system or g <br /> 1 equipment variable capacity system: <br /> Lighting equipment R404.1 At feast 75%of permanently installed lighting fixtures shall be high-efficacy lamps. <br /> FLORIDA BUILDING CODE-ENERGY CONSERVATION,6ttt EDITION(2017) R-57 <br />